Safety notes
Avoid danger due to damaged external transformer
connection cables. In the case of damage, the
external transformer connection cables must be
replaced by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug power supply is only suitable for indoor use.
• The function unit and plug-in connectors must not be
directly or indirectly sprayed with water when cleaning.
• The voltage supply must be separately switchable.
Application
Can be used in conjunction with:
• pressurised storage heaters,
• thermally-controlled instantaneous heaters,
(Only in conjunction with bath shower mixer 36 058)
• hydraulically-controlled instantaneous heaters.
(Only in conjunction with bath shower mixer 36 058)
Use in conjunction with unpressurised storage heaters
(displacement water heaters) is not possible.
Specifications
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure
reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Voltage supply:
(plug power supply 120 V AC/6 V DC)
• Power consumption:
• Radio frequency:
• Transmitter power:
• Emergency voltage supply: 6 V lithium battery (type CR-P2)
• Type of protection:
• Water connection
Note
Major pressure differences between hot and cold water supply
should be avoided.
1
English
7.25 psi
14.5 - 72.5 psi
145 psi
232 psi
176 °F
120 V AC, 50/60 Hz
9 VA
2.4332 GHz
< 0.05 mW
- Function unit
IP 40
- Plug power supply
IP 40
- Battery unit
IP 66
cold - RH
hot - LH
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Approval and conformity
This device complies with part 15 of the FCC Rules (USA) and
with the RSS of the IC Rules (Canada).
Operation is subject to the following two conditions:
This device may not cause harmful interference, and this
device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the party
responsible for compliance may void the user's authority to
operate the equipment.
Electrical installation
Electrical installation work must only be
performed by a qualified electrician. This
work must be carried out in accordance with
the regulations according to IEC 364-7-701-1984
(corresponding to VDE 0100 Part 701) as well
as all national and local regulations.
Always switch off the power supply
before making electrical connections.
New installation
During installation, please note:
• The lid of the function unit must be removable to permit
maintenance work.
• The funcitonal unit must not be installed with the lid facing
downwards.
• The maximum permissible distance between the operating
panel of faucet 36 058 and the function unit is 3m.
Prepare the wall for the installation, refer to the dimensional
drawing on fold-out page I.
B
2
2500 V
212 °F