Description
3
Description
3.1
Product overview
1
7
6
5
16
15
14
12
Pos.
Designation
1
Hose connector for the air outlet
2
Lid
3
Lime container
4
Water container
2
5
Fill level indicator
6
Tube connection for the air inlet
7
Tensioning strap
8
Profile gasket, lime container
9
Grid insert
10
Filter mat
11
Soda lime, Dive Sorb S
3
12
Flat gasket (interior)
13
Return valve
14
Profile gasket, water container
15
Filter mat
16
Bypass
4
3.2
Feature description
The Dräger Air Purifier 5000 (DAP 5000) reduces the CO
content of the ambient air drawn in by the compressor. The air
that is drawn in is humidified and conducted through the soda
lime (Dive Sorb S) to reduce the CO
conducted through the soda lime and 1/4 is conducted through
the bypass. A return valve prevents the soda lime from drying
during periods of non-use.
3.3
Intended use
The DAP 5000 is installed upstream from a breathing air
8
compressor in order to reduce the CO
9
ambient air that is drawn in.
10
3.4
Limitations on intended use
Any use other than that mentioned in the "Intended use"
chapter shall be regarded as improper usage. The following in
11
particular is not permitted:
Use of the DAP 5000 with media other than air
Use of the DAP 5000 below the permitted negative
pressure
12
Use of the DAP 5000 at overpressure, e.g. after a
compressor
Use of the DAP 5000 without suitable CO
13
according to EN 12021)
4
Use
4.1
Installation
CAUTION
For mobile applications, e.g. on ships, secure the DAP 5000
against slipping. The handles of the water and lime containers
can be used for mounting on the wall or the floor.
2
content. 3/4 of the air is
2
concentration of the
2
monitoring (e.g.
2