Oase BioPress 6000 Instrucciones De Uso página 11

Ocultar thumbs Ver también para BioPress 6000:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
− Minimum safety distance between the unit and the water: 2 m.
− Ensure that the power connection cable cross section is not smaller than that of the rubber sheath with the
identification H05RN-F. Extension cables must meet DIN VDE 0620.
− Protect the plug connections from moisture.
− Only plug the unit into a correctly fitted socket.
Safe operation
− Never operate the unit if either the electrical cables or the housing are defective!
− Do not carry or pull the unit by its electrical cable.
− Route all cables such that damage is excluded and nobody can trip over them.
− Never open the unit housing or its attendant components, unless this is explicitly required in the operating
instructions.
− Only use original spare parts and accessories for the unit.
− Never carry out technical modifications to the unit.
− Only have repairs carried out by customer service points authorised by OASE.
− The power connection cables cannot be replaced. When the cable is damaged, the unit or the component needs to
be disposed of.
− Only operate the unit if no persons are in the water!
− The unit, the connections and plugs are not water-proof and must not be routed or installed in water.
− Keep the socket and power plug dry.
Installation
Oase recommends hoses suitable for a minimum pressure of 1 bar.
Fig. A:
− BioPress 6000/10000: Shorten stepped hose adapters such that the connection opening coincide with the hose
diameter. This helps to avoid pressure loss.
− Push the union nuts over the stepped hose adapters, push or turn on the stepped hose adapter, and secure with the
hose clips.
− Insert the flat sealing ring or the O ring into the union nut for the black hose adapter and screw onto the pressure
filter inlet.
− Insert the flat sealing ring including the flow indicator flap for the transparent stepped hose adapter, then screw onto
the pressure filter outlet.
The cleaning effect of the pressure filter can be checked at the transparent stepped hose adapter with flow indicator
flap.
Installation
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
− Only operate the unit with the protection hood fitted.
− Ensure that the unit is installed water-tight with a safety distance from the water of a minimum of 2 m.
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
Figure B:
− Place the pressure filter in a flood protected position at a distance from the pond edge of at least 2m on firm and
level ground. As an alternative, the filter can also be partly buried up to approx. 5 cm below the closing clamps.
− The height difference between the filter lid and the free outlet point may be max. 2 m.
− Ensure unrestricted access to the cover to be able to carry out work on the unit.
- GB -
11
loading