Portacool APEX Serie Manual Del Propietário página 27

Idiomas disponibles

Idiomas disponibles

MAINTENANCE
Important Reminder: Safety First!
Before you start maintenance on your Apex evaporative cooler, disconnect the power by unplugging the cord from
the outlet. Always perform maintenance in a safe area.
Regular Maintenance
1. Drain the Reservoir Weekly: To ensure your cooler works efficiently, drain the water reservoir at least once
weekly. This will help minimize any order due to stagnant water. Remove the drain cap and let all the water drain
out. Check inside the reservoir for any dirt, debris, or scale build- up, and clean it as needed. When replacing
the drain cap, ensure its hand-tightened but not overly tightened.
2. Clean the Evaporative Media: To maintain optimal performance, periodically clean the evaporative media to
remove dirt, debris, or scale build-up. Use clean water from a hose (a spray nozzle) and a soft bristle brush to
clean the outer edges of the media. For more detailed cleaning instructions, refer to our online product support
page.
3. Address Hard Water Issues: If your water quality is less than ideal due to hard water, you can purchase Portacool
Hard Water Treatment™ at www.portacool.com/shop or from an authorized distributor. This treatment changes
the ionic structure of minerals in your water, keeping them off the media. It enhances cooling efficiency, pre-
vents scale build-up, reduces equipment corrosion, and prolongs the life of the evaporative media.