Alert Code Alert Text
1.2
FAN ERR
Cont.
2.1
PUMP ERR
2.2
PUMP ERR
Description
Possible Causes & Remedies
The load on the fan is
2. If an extension cord is being used, make sure it
higher than expected
3. Have a certified electrician inspect the wall outlet
The pump does not
1. Turn cooling mode to Max Cooling and listen for
appear to be running
as intended
2. Check for broken or pinched wires or connectors.
3. Check the pump connector attachment to the con-
The load on the pump
1. If an extension cord is being used, make sure it
is higher than expected
ALERT CODES
meets the size and length requirements in the
Safety section of this manual. Remove/replace if
necessary.
circuit.
water circulation and look for proper media wet-
ting. If water is not circulating, disconnect power
and proceed to step 2.
If wires are damaged do not attempt to repair, in-
stead replace the pump.
trol module to ensure the fit is snug. Unplug and
clean out terminals if necessary. Plug in and re-
check pump operation. Replace the pump if nec-
essary.
meets the size and length requirements in the
Safety section of This manual. Remove/replace if
necessary.
21