Ferroli BlueHelix ALPHA C Instrucciones De Uso, Instalación Y Mantenimiento página 277

Ocultar thumbs Ver también para BlueHelix ALPHA C:
Idiomas disponibles
  • ES

Idiomas disponibles

BlueHelix ALPHA C
Index Description
P42
Burner shutdown in DHW
Comfort mode activation
P43
temperature
Comfort mode deactivation
P44
hysteresis
P45
DHW standby time
P46
DHW user max. setpoint
DHW pump Post-Circula-
P47
tion
P48
Max. output in DHW
P49
Not implemented
P50
Not implemented
Burner shutdown in DHW
P51
(P42=2)
Burner ignition in DHW
P52
(P42=2)
P53
Solar standby time
P54
System pre-circulation time 0 ÷ 60 seconds
P55
System filling mode
Minimum system pressure
P56
limit value
System nominal pressure
P57
value
Maximum system pressure
P58
limit value
P59
Not implemented
P60
Frost protection power
P61
Minimum power
P62
Fan minimum speed
P63
Fan on speed
P64
Fan maximum speed
P65
Not implemented
EN
Range
0 = Fixed
1 = Linked to setpoint
2 = Solar
0 ÷ 80°C
0 ÷ 20°C
30 ÷ 255 seconds
40 ÷ 65°C
0 ÷ 255 seconds
0 ÷ 100%
--
--
0 ÷ 100
OFF = DHW user setpoint + P51
0 ÷ 100
ON = DHW user setpoint - P52
0 ÷ 255 seconds
0 = Disabled
1 = Automatic
0-8 bar/10 (Only for boilers with water pressure sen-
sor)
5-20 bar/10 (Only for boilers with water pressure sen-
sor)
25-35 bar/10 (Only for boilers with water pressure sen-
sor)
--
0 ÷ 50% (0 = minimum)
0 ÷ 50% (0 = minimum)
DO NOT MODIFY
(The parameters are automatically updated)
DO NOT MODIFY
(The parameters are automatically updated)
DO NOT MODIFY
(The parameters are automatically updated)
--
cod. 3540000021 - Rev. 00 - 02/2024
Default
0
40
20
120
55
30
100
--
--
10
10
10
30
0
4
7
28
--
0
0
G20/G230:
24 kW = 76
28 kW = 85
34 kW = 70
G30/G31:
24 kW = 73
28 kW = 83
34 kW = 68
G20/G230:
24 kW = 200
28 kW = 200
34 kW = 200
G30/G31:
24 kW = 186
28 kW = 192
34 kW = 192
G20/G230:
24 kW = 204
28 kW = 170
34 kW = 200
G30/G31:
24 kW = 176
28 kW = 165
34 kW = 188
0