4.7 - MENU OF ADVANCED FUNCTIONS
To access the advanced features menu, press and hold the MENU button for longer than 5 seconds.
Use the UP and DOWN buttons to scroll through the available features.
While displaying a function, the control unit will alternate the display of the item to the value set in it.
To change the value of the parameter you are viewing proceed as follows:
Press and hold the menu key for at least 3 seconds, the currently set value flashes.
Use the UP and DOWN keys to select the desired value.
Confirm the value by holding down the MENU key for at least 3 seconds.
To exit quickly press the MENU button.
Mode of intervention of the impact sensor
• Adjust this parameter according to current regulations.
Determines which areas of the stroke the impact sensor is in.
PARAMETER
SnM
Intervention time of the impact sensor
It determines how long the impact sensor takes after reaching the obstacle (blocked motor).
PARAMETER
Sit
Impact sensor disabling time at motor start
Determines how long the impact sensor is disabled at the start of handling.
PARAMETER
Sdt
Duration of the acceleration ramp
Time it takes the gate to switch from stationary to moving speed.
PARAMETER
UrA
26 - English - Translated from the original language
PARAMETER LIST
VALUES
OFF = disabled
1 = Normal speed area + Slowdown area
2 = Only normal speed area
3 = Only slowdown area
VALUES
from 1 to 10 multiplied by 100 ms
VALUES
from 0 to 30 multiplied by 100 ms
VALUES
from 0 to 30 multiplied by 100 ms
NOTE
DEFAULT
2 = Only normal speed area
DEFAULT
5 = 500 ms
DEFAULT
15 = 1500 ms
DEFAULT
15 = 1500 ms