HR Matic BIOS1 RNS HR Serie Manual De Instalacion Y Uso página 60

Idiomas disponibles

Idiomas disponibles

LEARNING WITH PERSONALIZED SLOWDOWNS
With personalized learning, the amplitudes of the slowdowns are adjusted by the user during the learning procedure.
• Check that during the first movement the display displays "LOP" and the gate moves in the OPENING
DIRECTION.
If necessary, press the DOWN button and then the SS button to reverse the movement.
• In order for the automation and all the safety devices installed to function correctly, it is
necessary to verify the correct direction of the automation movement.
• If the procedure starts while the limit switches are active, or if a safety device is involved during movement,
the procedure is stopped and the words " L--" appear on the display.
Carry out the appropriate checks and press the SS button to resume learning from step 3.
Unlock the transmission of the gear motor and carry the gate by hand
1.
halfway.
Then insert the motor transmission again.
Set the P value to the LSI parameter in the base menu to enable the
2.
function.
Press the UP button and the MENU button simultaneously for at least
5 seconds until the display shows " LOP ".
3.
At this stage the gear motor moves in search of the opening limit
switch.
Verify that the automation moves in the opening direction.
Once the opening limit switch has been reached, the automation
4.
automatically moves into closing.
At this stage the display shows " LCL ".
When the automation reaches the desired slowdown start position
press the SS button.
5.
The automation continues the movement until the closing limit switch
is reached and the flashing light remains fixed.
Once the closing limit switch is reached, the automation automatically
6.
moves to the opening.
At this stage the display shows " LOP ".
When the automation reaches the desired slowdown start position
press the SS button.
7.
The automation continues the movement until the opening limit switch
is reached and the flashing light remains fixed.
Once the opening limit switch has been reached, the automation
8.
moves in closing at full speed and with customized slowdowns.
9.
After the procedure the control unit displays "Ldone"
22 - English - Translated from the original language
DANGER
NOTE

UP
MENU
DOWN

SS

UP
MENU
DOWN

SS

UP
MENU
DOWN

SS


6-1622467M - rev. 0 - 07/03/2024

loading

Este manual también es adecuado para:

Bios1 230v rns hrBios1 120v rns hr