RS Pro RS-12T Manual De Instrucciones página 5

Multímetro digital de bolsillo
Idiomas disponibles
  • ES

Idiomas disponibles

Pocket Digital Multimeter / English
4-7 Diode Measurements
1. Insert the black test lead banana plug into the negative COM jack and the red test
lead banana plug into the V Hz Ω
2. Turn the function switch to Ω
position. Use the MODE button to select the
diode function if necessary (diode symbol will appear on the LCD when in Diode test
mode)
3. Touch the test probe tips to the diode or semiconductor junction under test. Note the
meter reading
4. Reverse the test lead polarity by reversing the red and black leads. Note this reading
5. The diode or junction can be evaluated as follows:
• If one reading displays a value (typically 0.400V to 0.900V) and the other reading
displays OL, the diode is good.
• If both readings display OL the device is open.
• If both readings are very small or '0', the device is shorted.
Note: when set this position , Date Hold and black light function cannot used.
4-8 CAPACITANCE MEASUREMENTS
WARNING: To avoid electric shock, disconnect power to the unit under test and
discharge all capacitors before taking any capacitance measurements.
Remove the batteries and unplug the line cords.
1. Set the rotary function switch to the
2. Insert the black test lead banana plug into the negative COM jack.
Insert the red test lead banana plug into the positive V jack.
3. Press the MODE button to indicate "nF" on the display.
4. Touch the test leads to the capacitor to be tested.
5. The test may take up to 3 minutes or more for large capacitors to charge.
Wait until the readings settle before ending the test.
6. Read the capacitance value in the display
4-9 Frequency Test
1. Set the function switch to the Hz Position.
2. Insert the black test lead banana plug into the negative COM jack and the red test
lead banana plug into the V Hz Ω
3. When Test current Frequency , Place the current fork around the middle of the test
lead.
4. Read the Frequency value on the display.
5. The display will indicate the proper decimal point and value.
6
positive jack
Ω CAP position.
positive jack.
5. Specifications
Function
Range
Resolution
600.0mV
0.1mV
6.000mV
1mV
DC Voltage
60.00V
10mV
600V
0.1V
Maximum Input: 600V DC
AC voltage bandwidth: 50 to 1000Hz(sine) 50/60( all wave)
6.000mV
1mV
AC TRMS
Voltage
60.00mV
10mV
(Auto Range)
600.0V
100mV
Maximum Input: 600V AC
100.0 A
0.1A
DC Current
Over rang protection: Maximum input 100A
600.0Ω
0.1Ω
6.000kΩ
60.00kΩ
10Ω
Resistance
600.0kΩ
100Ω
6.000MΩ
1kΩ
60.00MΩ
10kΩ
Input Protection: 250V dc or 250V ac rms.
99.99nF*
0.01nF
999.9nF
0.1nF
9.999μF
0.001μF
99.99μF
0.01μF
Capacitance
999.9μF
0.1μF
(Auto-ranging)
9.999mF
0.001mF
99.99mF
0.01mF
Input Protection: 250V dc or 250V ac rms.
*< 99.99nF(no specification)
Pocket Digital Multimeter / English
Accuracy
±0.8% of rdg + 2digits
±1.5% of rdg + 2digits
±1.5% of rdg + 5digits
±3.0% of rdg + 5digits
±1% of rdg + 4digits
±1.5% of rdg + 2digits
±2.0% of rdg + 5digits
±3% of rdg + 8digits
±(4.5% reading + 20 digits)
±(3.0% reading + 5 digits)
±(5% reading + 5 digits)