Brita mypure P1 Manual De Instrucciones página 11

Ocultar thumbs Ver también para mypure P1:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
6 Technical data of the P 1000 cartridge
Operating pressure
Water intake temperature
operation
Ambient tem-
perature for
storage/transport
Capacity up to carbon-
ate hardness 10 °dH at
setting "A"
Capacity from carbonate
hardness 10 to 17 °dH at
setting "B"
Capacity from carbonate
hardness 17 to 24 °dH at
setting "C"
Nominal flow
Pressure loss by nominal service flow
Empty filter cartridge volume 1 L
Weight (dry/wet)
Filter system
(filter head
with filter
cartridge)
Filter
Dimensions
c artridge
(Width/Depth/
Height)
Installed
dimensions
(vertical
installation
with wall
mounting
bracket)
Operating position
2 bar to max. 8.6 bar
4°C to 30°C
4°C to 40°C
–20°C to 50°C
P 1000
Up to 1200 L
P 3000
Up to 3400 L
P 1000
Up to 600 L
P 3000
Up to 1700 L
P 1000
Up to 400 L
P 3000
Up to 1100 L
60 L/h
0.25 bar
1 L
P 1000
1.0 kg/1.6 kg
P 3000
1.8 kg/2.8 kg
P 1000 119 mm/108 mm/265 mm
P 3000 117 mm/104 mm/417 mm
P 1000 108 mm/108 mm/259 mm
P 3000
104mm /104mm/410mm
P 1000 137 mm/130 mm/265 mm
P 3000
137mm/128mm/417mm
Horizontal and vertical
Water inlet connection
Water outlet connection
7 Troubleshooting
A No water flow
Cause:
Water intake closed.
Troubleshooting:
O pen the water intake at the upstream shut-off
valve or by closing the locking handle (3) on the
filter head. Check hoses for kinks.
B No or low water flow in spite of open water intake
Cause:
Mains pressure too low.
Troubleshooting:
C heck mains pressure. If the fault continues,
check the filter system and filter cartridge and
replace if necessary. Check hoses for kinks.
Cause:
F ilter head not mounted in direction of water
flow / hoses wrongly connected.
Troubleshooting:
D ismantle filter head and hoses and install in
direction of water flow (chapter 3.4).
C Leak
Cause:
Screwed connections not fitted correctly.
Troubleshooting:
C heck mains pressure. Check all screwed
c onnections and mount as described in
c hapter 3.4.
D LED not blinking
Cause:
B attery is not inserted in a correct way or is
used up.
Troubleshooting:
C heck if battery is inserted properly.
If necessary, replace the battery.
Cause:
Battery is empty.
Troubleshooting: Replace the battery.
G3/8"
G3/8"
11
ENGLISH