2 PRODUCT DESCRIPTION

Models and contents of the package
The name PASS identifies a series of electromechanical barriers with different characteristics with regard to the motor power sup-
ply, the speed of movement and the maximum length of the boom. All motorized models foresee the use of advanced control units
(NET series) equipped with anti-crush sensor, built-in 433 MHz radio receiver, speed adjustment and slow down during opening and
closing.
The PASS model is intended for residential use or small car parks.
The choice of barrier depends on the width of the access area and the expected duty cycle.
The DEA System complementary accessories are indicated in the table "PRODUCT ACCESSORIES" (pag. 114).
PASS vehicular barriers are composed by an electromechanical operator which puts in rotation the boom directly, while the balan-
ce is assigned to a compression spring.
The automation together with the control panel, is enclosed in a painted sheet metal box (or steel) with a lockable door.
Transport
PASS is always delivered packed in boxes that provide adequate protection to the product, however, pay attention to all informa-
tion that may be provided on the same box for storage and handling.

3 TECHNICAL DATA

Motor power supply voltage (V)
Absorbed power (W)
Type of boom used
Duty cycle (cycles/hour)
Maximum n° of operations in 24 hour
Built-in capacitor (µF)
Operating temperature range (°C)
Motor thermal protection (°C)
Opening time 90° (s)
Weight of product with package (Kg)
Protection degree
Power supply (V)
Rated power transformer (VA)
Fuse F2 (A) (transformer)
Batteries
Fuse F1 (A) (batteries input)
24V operators outputs
Warning: The above values are calculated by taking the maximum power
supplied by the respective processors. In absolute terms, the maximum current
from each output must not exceed 10A.
Auxiliaries power supply output
"Warning" output
Electric lock output
Flashing light output
Operating temperature range (°C)
Receiver frequency
Transmitters type of coding
Max remote controllers managed
20
PASSNET/V
PASSNET/L
230 V ~ ±10% (50/60 Hz)
260
3000
2,4 s

CONTROL BOARD

NET24N
230 V ~ ±10% (50/60 Hz)
150 VA (230/22V)
2A
2x 12V 4A
15A
2x 5A
+24 V
max 200mA
+24 V
max 15 W
max 5W or max
24V
1 art. 110
24 V
max 15W
-20÷50 °C
433,92 MHz
HCS fix-code - HCS rolling
code - Dip-switch
100
OPERATOR
PASSNET/VR
PASS24NET/V
320
Refer to Table on page 113
80
200
1000
2400
3500
8
-20÷50 °C
140 °C
7,3 s
3 s
42
IP34
Power supply (V)
Fuse F2 (A)
Fuse F1 (A)
230V operators outputs
Auxiliaries power supply output
"Warning" output
Electric lock output
230V Flashing light output
24V Flashing light output
Operating temperature range (°C)
Receiver frequency
Transmitters type of coding
Max remote controllers managed
PASS24NET/L
PASS24NET/VR
24 V
105
290
140
240
1200
280
-
-
2,2 s
6 s
2,8 s
41
NET230N
230 V ~ ±10% (50/60 Hz)
5A
160mA
2 x 600W
+24 V
max 200mA
230 V ~ max 2x 40W
max 1 art. 110 or 24V
output max 5W configurable
230 V ~ max 40W
24 V
max 100mA
(for led flashing light) art.
LED24AI
-20÷50 °C
433,92 MHz
HCS fix-code - HCS rolling
code - Dip-switch