Johnson VARICP86T Manual De Instrucciones página 76

Mando por cable
Elemento de
Nombre del parámetro
ajuste de la
IDU
Set od.temp.value(aux
heater on)
Set outdoor temp.
when the third-
party heater works
Ajuste de la
IDU
separately
Upper limit of
automatic fan speed in
cooling mode
Upper limit of
automatic fan speed in
heating mode
Air flow setting at fan
Ajuste de la
velocidad del
speed 7
ventilador
Fan speed setting in
heating standby mode
Time to stop the fan of
IDU in heating mode
(Thermal)
Rango del
parámetro
Celsius: de −5 a 20
Fahrenheit: de 23
a 68
00/01/02/03/
04/05/06/07/
08/09/10/11/
12/13/14/15/
16/17
04/05/06/07
04/05/06/07
00/01
00/01/14
00/01/02/03/04/
FF
73
Observaciones
1 °C o 1 °F
00: Sin límite; 01: -16 °C/4 °F;
02: -14 °C/7 °F; 03: -12 °C/10 °F;
04: -9 °C/15 °F; 05: −7 °C/20 °F;
06: -4 °C/25 °F; 07: -1 °C/30 °F;
08: 2 °C/35 °F; 09: 4 °C/40 °F;
10: 7 °C/45 °F; 11: 10 °C/50 °F;
12: 13 °C/55 °F; 13: 16 °C/60 °F;
14: 18 °C/65 °F; 15: 21 °C/70 °F;
16: 24 °C/75 °F; 17: 27 °C/80 °F
04: Velocidad 4; 05: Velocidad 5;
06: Velocidad 6; 07: Velocidad 7
04: Velocidad 4; 05: Velocidad 5;
06: Velocidad 6; 07: Velocidad 7
00: Velocidad constante;
01: Flujo de aire constante
00: Térmico; 01: Velocidad 1;
14: Velocidad del ventilador
antes de pasar al modo Standby
00: Ventilador encendido; 01: 4
min; 02: 8 min; 03: 12 min;
04: 16 min; FF: DIP de la placa
principal