Factory Setting; Pause Time Setting - Lincoln Quicklub V10 Instrucciones De Funcionamiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

User Manual
Operating Instructions
PCB 5
Jumper position:
Preselection of the time ranges
IMPORTANT
If the operating voltage is < 120 VAC the
pause time must not fall below 16
minutes.
6001a02
If the operating voltage is < 120 VAC the
lubricating time must not exceed 8 min.
PCB 6
Rotary switch for pause time, blue
Switch position
1
Minutes
4
Hours
1
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
T-PCBv-020d10
T-PCBv-020c10
2
3
4
5
8
12
16
20
2
3
4
5

Factory Setting

Pause time
V10
6 h
V11
6 h
V12
24 min.
V13
24 min.
IMPORTANT
Adjacent ICP plug-in positions are used
exclusively by the manufacturer.
6001a02

Pause time setting

The pause time can be set to 15 different settings by
means of the blue rotary switch.
Depending on the position of the jumper (see fig. PCB 5)
the necessary time interval is adjustable (4-60 minutes or
1-15 hours).
NOTE
During switching position 0 a failure report
at the light emitting diode takes place on the
right LED 3 (see fig. PCB 8).
At the same time the factory-set pause time
6001a02
is accepted.
6
7
8
9
24
28
32
36
6
7
8
9
2.6EN-28006-E11
Lubricating time
H
6
6 min.
(1-15)
h
6
24 sec.
(1-15)
min
6
6 min.
(4-60)
min
6
24 sec.
(4-60)
A
B
C
D
40
44
48
52
10
11
12
13
min
3
(2-30)
S
3
(8-120)
min
3
(2-30)
S
3
(8-120)
E
F
56
60
14
15
Page 7 of 22