Programming is usually performed in-house, but user can gain access to this section to check or edit values, if needed.
After switch-on, when Press + is displayed, hold down Prog until parame-
ter page is displayed. It is possible to enter the parameter environment,
even from status page.
PARAMETER PAGE
Use Prog, + and - keys to set:
um
: unit of measurement.
Set 0 to measure in metres.
Set 1 to measure in feet.
ton
: time (sec) of piston pulse. If time is decreased, stroke is shorter and
closing movement is slower.
toff : time (sec) of pulse-to-pulse pause.
step : number of pulses to output to piston.
pt : potentiality.
m2 : set 1 for outlet valve.
set 0 for closing valve.
imp/l : set used litre counter value.
F(x) : 1 Choose the valve detecting pressure loss and will open again detecting again pressure
F(x) : 64 Allows to send the message without calling, for this option it's necessary to program just one mobile phone number
F(x) : 6 to be set when having the ELCOS panel to control the pump unit
"USER" STRUCTURE
Set :
diameter
roller width,
number of teeth of rack.
Number of pulses on the scroll bar per one drum revolution ( only
for machines with chain drive)
DATA OF STRUCTURE CHOSEN
Set :
hose length,
ovalization
hose diameter.
SECOND SPRINKLER
Allows to manage the second sprinkler on the trolley lift by the com-
puter . In this case choose "1" if not choose "0"
IRRIGATION - MANAGER
If not shown "0" is automatically displayed in the mask
If shown, the irrigation manager ID must be set in the mask
WI-FI
"1" when the system includes the device to count the laid-down me-
ters of hose
"0" if this device is not in the system
SETTING DATE AND TIME
It is possible to set current hours (h), minutes (min), day (gg), month
(m) and year (a).
The fert function is not active and shall not be set.
PROGRAMMING THE MAIN PARAMETERS
EN
40