Adler europe AD 7751 Manual De Uso página 14

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
operate without the temperature setting and the temperature setting indicator (E) will disappear from the display and the display will
show "- - ".
NOTE: when the temperature is not set, the device after 12 hours of continuous operation will cool down itself by cool fan blowing by
30 seconds and the device enters into standby mode automatically.
6. Weekly program setting
After complete setting the current TIME/DAY, below are the steps to set weekly program:
STEP 1: Press the power button (A) on the remote control (7), the device enters into working status.
STEP 2: Press the weekly program button (P), the display (4) shows letter "P" to communicate it enters into weekly program setting.
STEP 3: Press the "DAY" button (R), the display (4) shows "d1", again press "DAY" button (R) repeatedly to set to working day,
choose Monday-Sunday: d1~d7. Example setting for Monday – look at Figure 9B.
STEP 4: Press the "EDIT" button (S), the display shows P1 (first period) as default, again press the "EDIT" button (S) to set time
period between P1-P6.
NOTE: The device can only remember 6 time periods as maximum for each working day, while setting any time and adjust
temperature. Follow steps 5-7 below to set turn on time and turn off time and desired temperature for each time period (P1-P6).
Example setting P1 – look at Figure 9C:
STEP 5: Press the "TIME/ON" button (U), the display shows "00" as default. Repeatedly press the "TIME/ON" button (U), one
pressing increase the time by one hour, to set the turn-off time between 00-24 hours. Example of setting the turn-on time 7:00 a.m. is
shown at Figure 9D.
STEP 6: Press the "TIME/OFF" button (W), the display shows the previous turn-on time by default. Repeatedly press the "TIME/OFF"
button (W), one pressing increase teh time by one hour to set the turn-off time between 00-24 hours. Example of setting the turn-off
time 13:00 p.m. is shown at Figure 9E.
NOTE: Set up time off cannot be earlier than set up time on. When fixed" TIME/ON " is the same as" TIME/OFF ", the device enters
into standby mode.
STEP 7: Press the PLUS button (K) or the MINUS button (L) to set the desired temperature from range 10-49 degree of Celsius.
STEP 8: Repeating steps 3-7 above, you can set the weekly program for the working days you want.
STEP 9: Then press the "OK" button (M) to confirm the setting.
10). To cancel the weekly program function, press the weekly program button (P) again, the light "P" on the display will disappear.
The weekly program is off.
After the above setting are completed and weekly program is working, you can check with all set up parameters by pressing the
"DAY" button (R) to check set working day (d1-d7), by pressing the "EDIT" button (S) to check time periods (P1-P6), by pressing
"TIME/ON" button (U) to check the set turn-on time (hour), press "TIME/OFF" button (W) to check desired turn-off time for each
period.
NOTE: The device has not got the memory function. After cut the power supplied, the device needs to be reset.
7. Open-window detection mode setting
7.1 Press the power button (A) on remote control (7), the device enters into working status. Let the device to heating, for a moment
until stable.
7.2 Press the open window mode button (B), the open window mode indicator (B1) will lighted up, the temperature "23" is displayed
by default. Press the PLUS button (K) or the MINUS button (L) to set target temperature. If detected temperature decrease, the device
will stop working. Then press the power button (A) to turn on the device.
7.3.Press the open window mode button (B) again to turn off the open-window detection, the open window mode indicator (B1) will
disappear from display (4) and the device will resume to previous working mode. An example to set 23 degree of Celsius during open-
window detection is shown at Figure 10H.
7.4. When turn on open-window detection mode and weekly program at the same time, during the OFF period of weekly program, the
device is designed to doesn't work.
7.5. During the working status of weekly program, the temperature is subject to the setting temperature of open-window detection
mode. An example at Figure 10.I .
V. Installation
1.Fix the device horizontally on a vertical wall, the display toward the ground without inclining it. Other position is hazardous.
2.Keep minimum distance without other object / obstruction around installed device as shown at Figure 12.
3. The screws and wall plugs supplied are suitable for solid walls. For all other types of wall, please use suitable screws and wall
plugs.
4.Drill two holes in wall and have a distance 354mm and follow up the Figure 13 to hang the device on the wall correctly.
VI. Battery replacement
BATTERY WARNING: KEEP OUT OF REACH OF CHILDREN
The remote control requires 1 piece of CR2025 3V lithium battery (not included).
- Open the battery compartment by sliding the cover down.
- Insert the battery into the battery's chamber – look at Figure 11.
14
loading