- press the button (F) first time for room temperature fan operation – display will looks as at Figure 4A.
- press the button (F) second time to heat on low power 1000W - display will looks as at Figure 4B, one the Sun icon is visible.
- press the button (F) third time to heat on high power 2000W - display will looks as at Figure 4C, both the Sun icons are visible.
- press the button (F) forth time to enter into standby mode - display will looks as at Figure 3, letter S (that means standby mode) is
visible.
On standby mode the device will operate by 30 seconds with cool fan blowing to let the device cool down inside to ensure long
lifetime and switch off the fan.
NOTE: IF OVERHEAT PROTECTION CAUSES THE DEVICE TO SHUT OFF, PLEASE DISCONNECT IT FROM THE PLUG FOR A
FEW MOMENTS BEFORE STARTING IT AGAIN.
3.Timer function – manual operation
- To set up the time of device operation before automatic switch off press the button (G) in working status. Repeating pressing the
button (G) one time increases one hour timer operation from 00 to 12 hours. After setting desired period, the display will show it for 5
seconds, then resume to previous display and the indicator (G1) will show on the display panel (4). On Figure 5 is shown an example
of setting 8 hours.
- To set up the delayed start function, the device need to be in standby mode. Then press the button (G) repeatedly to set up delayed
start time in range of 00-12 hours. After completing setting, the display (4) shows the turn-on time and the indicator (G1). When the
turn-on time arrived, the device will automatically turn on - start to operate. On Figure 6 is shown an example of set turn-on time to 8
hour.
NOTE: if no setting the temperature and no setting the weekly program, the device will turn off AUTOMATICALLY after 12 hours of
continuous operation.
IV. Function operation by remote control (7)
NOTE: During the operation of the remote control (7), the transmitting head must be aligned with the receiving area of the product to
avoid insensitivity.
The remote control (7) can be normally used within 3 meters in front of the device and in the left and right angles of 60 degrees.
1.After plug in and switch on the device by pressing the main power switch (1), the device enters into standby mode and digital
display (H) shows letter S – look at Figure 3.
2. To set up fan mode:
- press the button (A) first time for room temperature fan operation – display will looks as at Figure 4A.
- press the button (F) second time to heat on low power 1000W - display will looks as at Figure 4B, one the Sun icon is visible.
- press the button (F) third time to heat on high power 2000W - display will looks as at Figure 4C, both the Sun icons are visible.
- press the button (F) forth time for room temperature fan operation – display will looks as at Figure 4A.
- press the button (F) fifth time to work over and over again, starting with low power 1000W heating.
To switch off the fan mode, press button (A) on remote control (7), then the device enters in standby mode and display will looks as at
Figure 3.
3. Timer function:
It is operated same way for manual operation and remote control operation. Read point 3 in Chapter III Function operation (touch
panel – manual operation).
4. Time/Day setting – it is obligatory to set up present time and day to let the device operate in weekly program mode.
The Time/Day setting can be set up on both status when the device is working as well as when the device is on standby mode.
4.1 Press the "SET" button (J) for one time, the display shows "12" as default, press the PLUS button (K) or the MINUS button (L) to
set current hour (00 to 23). Next press the "SET" button (J) again, the display shows minute "30" as default, next press the PLUS
button (K) or the MINUS button (L) to set current minutes "00 to 59".
4.2 Press the "SET" button (J) again to display the day of week, press the PLUS button (K) or the MINUS button (L) to set current day.
You will chose between: d1=Monday, d2=Tuesday, d3=Wednesday, d4=Thursday ,d5=Friday, d6=Saturday, d7=Sunday. Then press
"OK" button (M) to confirm the setting. The displays show the content before final confirmation. Figure 7 shows an example: Setting to
Wednesday, 9:30 a.m.
5. Temperature setting
During working status, press the PLUS button (K) or the MINUS button (L), the display shows "23"as default. Press the PLUS button
(K) or the MINUS button (L) to set desired temperature ( in range 10-49 degree of Celsius), next press "OK" button (M) to confirm the
setting. Then the temperature setting indicator (E) will occur on the display. An example: the current ambient temperature is 15
degree of Celsius, after set temperature to 25 degree of Celsius the display is shown at Figure 8.
The temperature level is adjusted by the device automatically according to below working rule is:
-When the temperature different between desired temperature you set up and present room temperature is more than 2 degree of
Celsius, the device operates with high heating level power 2000W.
-When the temperature different between desired temperature you set up and present room temperature is less or equal 2 degree of
Celsius, the device operates with low heating level power 1000W.
- When the desired temperature you set up and present room temperature are same, the device operates with cool fan for 30
seconds to let it cool down inside and next the device stops operation.
To cancel the temperature setting press fan mode selection button (F) to choose the heating level 1000W or 2000W. The device will