From this new page you can manage:
• Mot. Spd.
To set MIN and MAX speed on the 2 fans.
• Setp Byp
"Bypass" mode activates based on the temperature: "Setp
Byp" is selectable in a range between 15°C and 30°C
(default 18°C).
• No Frost
From "INSTALL" menu, selecting "NO FROST", you can enter
the "NO FROST" setting menu. From this new page, it is now
possible to choose the desidered function during the "NO
FROST" process. For more details on setting "NO FROST"
functions, see "NO FROST' page.
• Lifetime
To set the filter duration time, which can vary between 3, 6
and 12 months.
• Language
Language selection.
• Modbus ID
In the presence of another installed remote HMI user
interface, you can configure a different address than the
default one (which is "160").
• POSTHEAT
The variable that controls activation of the post-heater, if
present. The editable default value is: YES.
SETP BYP
018
NO FROST
UN - BALAN.
UN - BALAN.
HEATER
HEATER FORC
MBUS ID
160
ENGLISH
[ ▲ ]
[ ▲ ]
[ ▲ ]
[ ▲ ]
[ ▲ ]
[ ▲ ]
[ ▲ ]