Do not store the pressure washer outdoors or where it can freeze, the pump could be
severely damaged.
Cleaning the nozzle
-
A clogged or partially clogged nozzle can significantly reduce water output and cause
intermittent jetting. To clean the nozzle:
-
Turn off and unplug the unit.
-
Disconnect the water supply. Press the trigger 2 or 3 times to release the pressure trapped
in the hose.
-
Remove the lance from the trigger gun.
-
Turn the nozzle to concentrated mode to activate the internal blades.
-
Use the nozzle-cleaning needle provided or any pointy, thin item to clean the nozzle, e.g.,
insert an unfolded paper clip into the nozzle hole. Move it inwards and outwards until all
dust and dirt is removed. Fig. 8
-
Pour water through the nozzle hole into the nozzle to clean the dirt remains. To do this,
point a lighted garden hose at the nozzle for 30-60 seconds.
6. TROUBLESHOOTING
Problem
Smoke comes out of the
device.
There is not enough pressure.
The pressure washer does
not turn on.
Cause
Overheating, overloading, or
motor failure.
The water inlet filter is
clogged.
Air is entering from the hose
connections to the pump.
The nozzle or discharge valve
is worn or are not of the
correct size.
The unit is pressurised.
The plug is not properly
connected, or the socket is
defective.
The extension cord is too long
or short.
The supply voltage is too low.
The thermal safety switch
has tripped.
HY D ROB OOST 14 00 ES SEN TI A L
ENGLISH
Solution
Switch off the device
immediately and contact
the Technical Support
Service of Cecotec.
Clean the water inlet filter.
Check that the connections
and the locking ring are tight.
Contact the Technical Support
Service of Cecotec
Press the gun trigger.
Check the plug,
the socket, and fuses.
Remove the extension cord.
Make sure that the mains
voltage matches the voltage
stated on the rating label of
the appliance.
Switch off the device and
allow it to cool down.
69