A1 TECHNICAL DATA
Model THAEY
Nominal cooling capacity (*)
E.E.R.
Nominal cooling capacity (*) EN 14511:2013
EER (*) EN 14511:2013
ESEER EN 14511:2013
Nominal heating capacity (**)
C.O.P.
Nominal heating capacity (**) EN 14511:2013
COP (**) EN 14511:2013
Sound pressure (***) (∆)
Sound power (****)
Scroll/step compressor
Fans
Heat exchanger water content
Heat exchanger nominal flow water side (*)
Water side heat exchanger nominal pressure drops (*)
Residual head (P0 installation) (*)
Residual head (P1 installation) (*)
Residual head (ASP0 installation) (*)
Residual head (ASP1 installation) (*)
Tank water content
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Absorbed power in summer mode (*) (●)
Absorbed power in winter mode (**) (●)
Pump absorbed power (P0/ASP0)
Pump absorbed power (P1/ASP1)
Electrical power supply
Auxiliary power supply
Summer operation nominal current (*) (■)
Winter operating nominal current (**) (■)
Maximum current (■)
Starting current
Starting current with SFS accessory
Pump absorbed current (P0/ASP0)
Pump absorbed current (P1/ASP1)
Dimensions
Width (L) set-up P0-P1
Width (L) set-up ASP0-ASP1
Height (H)
Depth (P)
Water connections
(*) Under the following conditions: condenser
inlet air temperature 35°C; chilled water
temperature 7°C; temperature differential at
evaporator 5°C.
(**) In the following conditions: Evaporator inlet
air temperature 7°C D.B., 6°C W.B.; hot water
temperature 45°C; temperature differential at
condenser 5°C
(***) Sound pressure level in dB(A) referring to
a 10 m distance from the unit, in directionality
factor equal to Q=5.
(****) Sound power level in dB(A) on the basis
of measurements taken in accordance with UNI
EN-ISO 9614 and Eurovent 8/1 Standards
kW
kW
kW
kW
dB(A)
dB(A)
n° x kW
l
l/h
kPa
kPa
kPa
kPa
kPa
l
kW
kW
kW
kW
V-ph-Hz
V-ph-Hz
A
A
A
A
A
A
A
mm
mm
mm
mm
Ø
(∆) For machines fitted with the "SIL"
accessory, the sound pressure must be
corrected to -3dBA for models 122 ÷ 130.
(■) Total current value, including the current
absorbed by pump P1.
(●) Absorbed power by the unit without an
electric pump.
N.B.:
The E.E.R. calculation and C.O.P. gross
does not consider the electric absorption of the
pumps.
The performances according to EN 14511:
2013 relate to the fitting with P1 pump.
90
122
127
22,3
26,3
2,85
2,64
22,70
26,70
2,84
2,64
3,33
3,07
23,90
30,7
3,08
3,11
23,50
30,30
2,96
3,02
52
53
75
76
1/1
1/1
2x0,24
2x0,24
1,9
2,4
3828
4529
34,74
31,86
65
64
131
116
55
52
97
97
45
45
See serial number plate
See compressor plate
7,82
9,94
7,76
9,86
0,4
0,4
0,6
0,7
Water outlet
230-1-50
18
21
18,3
20,7
21
25
116
122
2,1
2,1
2,7
1,4
1230
1535
1522
1822
1290
1510
600
695
1 ½"
1 ½"
Compact-Y SM
130
28,6
2,47
29,00
2,45
2,81
34,4
3,14
34,00
3,02
53
76
1/1
2x0,24
2,6
4916
32,09
55
112
42
90
45
11,56
10,95
0,4
0,7
24,2
23,2
27
134
2,1
1,4
1535
1822
1510
695
1 ½"
L
P