Temperature control from the thermostat
Press the Up and Down keys on the central unit to set the desired
temperature.
Heating mode:
•
If the set temperature (SET) is higher than the temperature
in the room (ROOM), the central unit will send a command
to the receiver unit in a maximum of 90 seconds. The
"Heating on" LED on the receiver unit will light up and a
click will be heard indicating the activation of the internal
relay. The icon
screen of the central unit.
•
If the set temperature (SET) is lower than the temperature
in the room (ROOM), the central unit will send a command
to the receiver unit in a maximum of 90 seconds. The
"Heating on" LED on the receiver unit will go out and a click
will be heard indicating the activation of the internal relay.
The icon
Cooling mode:
•
If the set temperature (SET) is lower than the temperature
in the room (ROOM), the central unit will send a command
to the receiver unit in a maximum of 90 seconds. The
"Heating on" LED on the receiver unit will light up and a
User manual
(the heating system is on) appears on the
disappears from the screen.
12