Values above
999999m
cannot be
indicated;
"ERROR"
appears on
the display. Divide the volume
to be measured into individual
measurements; their values can
then be calculated separately
and then summarized.
CONTINUOUS MEASUREMENT
(Tracking) (see figure E)
For continuous measurements,
the measuring tool can be
moved relative to the target,
whereby the measuring value
is updated approx. every 0.5
seconds. In this manner, as an
example, you can move a certain
distance away from a wall, while
the actual distance can always
be read.
For continuous measurements,
press button 9 until the indicator
for continuous measurement
appears on the display. To start
the continuous measurement,
press the measuring button 2.
The current measured value is
displayed in the result line b.
Pressing the measuring button
2 ends the
continuous
measurement.
The last
measured value
is displayed
in the result line b. Pressing
3
the measuring button 2 again
restarts a continuous measuring
run.
Continuous measurement
automatically switches off after
5 min. The last measured value
remains indicated in the result
line b.
DELETING MEASURED
VALUES
Briefly pressing button 4
deletes the last individual
measuring value determined in
all measuring functions. Briefly
pressing the button repeatedly
deletes the individual measured
values in reverse order.
ADDING MEASURED VALUES
To add measuring values, firstly
carry out a measurement. Then
press the plus button 8. For
confirmation, "+" appears on the
display. Then carry out a second
measurement.
If you add volumes or areas,
then the small + sign which is left
of the volume/area symbol in the
display, appears during the 2nd /
3rd / 4th,....volume measurement
which is added.
-14-
To call up the
sum of both
measurements,
press the plus
button 8 again.