Thermador An American Icon HMWN30 Manual Del Usuario página 5

Ocultar thumbs Ver también para An American Icon HMWN30:
Idiomas disponibles

Idiomas disponibles

Parts In cluded with your Hood
«
Hood Canopy Assembly without blower
*
Grease filters
«
Drip tray for each filter.
«
Drip trays holding brakets + plastic washers and
knobs
«
1 Transition
withback draft damper
«
Use & Care / Installation Instructions
«
Fittings bag with:
4
Washers
6
Drywall anchors
2
Hooks with regulating screws
6
Screws 5X35
4 Screws for transition
Option al accessory
Duct covers only for 30" and 36"
Ductless recirculation kit available only for HMWN30
HMWN36 model.
Parts Not Included with your
Hood
«
Duct Tape
«
1/2" Conduit
«
Wire
Nuts
«
Round
Duct.
«
Wiring clamp
.
CAUTION!
Lamps
are not supplied,
use
ONLY 120 Volt, 50 Watt (maximum) 50°
halogen light made or a GU10 base,
suitable
for usei nopen
luminarie
.
«
4#10
pan head wood screws
for installation on
a bottom ofa cabinet
3 prong plug
Blowers
See sections for integral ventilator installation and remote
ventilator installtion for more blower details.
Tools required
Flat blade and Phillips screwdrivers
Pencil and tape measure
Metal snips (in some applications)
Electric drill
Saw
(saber
or keyhole)
Pliers
Level
Caulking
Flashlight
Wire stripper
Safety glasses
Gloves
Step ladder
INSTALLING THE HOOD
¢
Forthe
most efficient
air flow exhaust, use a
straight run or as few elbows as possible.
CAU TION:
Vent
unit to outside of
building, only.
*
Two people are necessary for installation.
On average
2 hours are necessary
to complete
installation
(without considering
cut to be done
on wall and or on cabinet,
installation of ducts ,
conduit and electrical
connections
to the mains).
installation
steps:
11 installation steps are required for both
installation methods
Wall mount installation
steps or in alternative
Cabinet installation
«
The hoodis fitted with Screws
and Drywall
Anchors suitable for most surfaces, consult a
Qualified Installer, check if they perfectly fit with
your cabinet/wall.
«
Do not use flex ducting.
«
COLD
WEATHER
installations should have an
additional backdraft damper installed to
minimize backward
cold air flow anda
nonmetallic thermal break to minimize
conduction of outside temperatures as_
part of
the ductwork.
The damper should be on the
cold air side of the thermal break.
The
break should be as close as possible to
where the ducting enters the heated portion of
the house.
«
Makeup
air: Local building codes
may require
the use of Make-Up Air Systems when using
Ducted Ventilation Systems
greater than
specified CFM
of air movement.
The specified CFM
varies from location to location
Consult your HVAC
professional for specific
requirements
in your area.
loading