TECHNICAL DATA
Voltage:
Transformer:
Output Motor:
Consumption max.:
Consumption Standby:
Supply accessories:
Operating temperature:
Modes:
Measurements:
Measurements Box:
Protection class Box:
Fuse:
Remote control:
Feasible frequencies:
TYPICAL CONFIGURATION OF AN INSTALLATION:
1. Operators (LYN/SCS)
2. Control board
3. Photocell (active for closing), max. height 200 mm
First photocell.
4. Photocell (active for opening and closing), max. height 200 mm
Second photocell (optional).
5. Flashing light (optional)
Important visual information on the movement of the gate.
6. Key-operated switch or wireless keypad (optional)
Is mounted on the outside. The gate is opened by key or by
entering a number.
7. Contact strip (optional)
Safeguards the gate on being touched. Contact strips can be
mounted on the gate or on the pillars. If required, contact strips
must be mounted at a height of up to 2.5m.
CONTROL BOX
The control consists of several components.
- exterior installation box
- cover for box
- control
- transformer
- baseplate (pre-assembled) 1
- cable bushing large
- cable bushing small
- fastening clips
- screws 3,5 x 9,5 mm
- large washer
- screw large
- spring lock washer
- cable lug
- nut M8
- washer M8
- large closure screws
PREPARATION
Open the 4 pre-cut holes at the bottom of the casing
with a screwdriver or a similar device. Attach large
cable bushing on the left then the rest as shown in
picture. Humidity and water destroy the control. All
openings and cable bushings must be sealed
against water (waterproof). The control box with the
motor control is to be mounted with the cable
bushings facing down.
230V~ ±10% 50-60Hz
230V/24V, 150VA
24V/DC
max. 400W (in operation)
max. 4 Watt (without accessories)
24VDc / 600mA max.
-25ºC ÷ 55ºC
Standard, Automatic
250x75mm (without box)
ca. 300mm x 220mm x 120mm
IP45
2 x 2A fast-blow
max. 170
433MHz, 868MHz
1
1
1
1
1
3
6
4
1
1
1
1
2
1
5
4
+
2/16 en