Rev.1 14/02/18
Pag.84
EN
Layout 2 (storage puffer management)
In this type of circuit, the storage puffer is managed by the stove due to a contact or immersion probe (optional) connected to the
back of the stove.
Below is shown the new "Stand-by" mode.
The operation is the same as for the basic layout except for the fact that in this layout, the boiler exchanges heat directly in the puffer;
when the temperature set is reached, the stove switches to ECO STOP mode and then restarts if the temperature drops below a
restart value (set by the installer upon testing).
Layout 3 (DHW boiler + storage puffer management)
The following layout combines the functions of the previous layouts and is recommended to stoves provided with a puffer without
internal coil preset for domestic hot water.
In this type of circuit, the boiler is managed by the stove due to a contact or immersion probe (optional) to be connected to the back
of the stove. The same applies to the control of the puffer that is provided by the thermostove through a contact or immersion probe
(not supplied) connected directly to the back of the stove.
Below is shown the new "Stand-by" mode.
The operation is the same as for the basic layout except for the fact that in this layout, the boiler exchanges heat directly in the boiler
(priority); when the temperature set is reached, the 3-way valve changes its position and the boiler starts exchanging heat within the
puffer. When the set temperature is reached, the stove enters in ECO STOP mode; it restarts if the temperature drops below a restart
value (set by the installer upon testing).
The 3-way valve is directed again into the boiler when:
- there is a request from the Boiler;
- there is a requested from the flow switch (optional, if connected).
The stove restarts from Eco-stop or Stand by mode according to storage puffer requests or boiler requests.
By setting the SUMMER function, the 3-way valve remains fixed in a single position, enabling the release of heat output
by the stove exclusively inside the boiler. As soon as this condition is reached, the stove switches to ECO STOP mode.
Use and maintenance manual RBH 150 V- RBH 200 V
T°C Puffer
From STAND BY mode, press
the ARROW key to
set the desired puffer T°C
Boiler water T°C
CANNOT BE CHANGED
T°C Boiler
From STAND BY mode, press
the ARROW key UP
to set the
DHW boiler T°C
that you desire.
T°C Puffer
From STAND BY mode, press
the ARROW key DOWN
to set
the desired puffer T°C
POWER MOD
PUMP
3-WAY VALVE
PUFFER
PRESSURE 1.1 BAR
HH T .
21°C
Press the key
"V" from STAND BY page
to display the actual states and
the room temperature
POWER
MOD
PUMP
3-WAY VALVE HEAT
3-WAY VALVE BOILER
HH T .
21°C
Press the key
"V" from STAND BY page
to display the actual states and
the room temperature