MAinTEnAnCE
Fig. 7
cover
Screws(10)
Belt Tensioner
Impeller
Pulley
NOTE: Verify that the washer is still in place on the impeller pulley shaft before reinstalling the belt cover.
• Reinstall the impeller pulley bracket with the three (3) screws.
• Reinstall the washer and the flange lock nut. Tighten the nut.
• Reinstall the belt cover with the ten (10) screws. in order to facilitate the installation,
position the narrow part of the cover into the recess of the housing and install the two
top screws and then push the rest of the cover down into recess and over the rotor shaft.
Tighten all ten (10) screws.
Impeller Pulley
Bracket
Screws(3)
16
Flange Lock Nut
Washer
Drive Pulley
Fig. 8
Belt
Fig. 9