TROUBLESHOOTING
Submersible Utility Pump Function
Problem
Pump does not start or run
Pump cannot pump water out
Non-Submersible Transfer Pump Function
Problem
The pump does not start or
run.
The pump does not prime.
The flow rate is too low.
8
Possible Cause
1.
The fuse is blown.
2.
The breaker is tripped.
3.
The plug is disconnected.
4.
The plug is corroded.
5.
The motor failed.
6.
Ice or blockage has locked the
impeller.
1.
The screen is blocked.
2.
The hose is kinked, bent sharply,
or coiled.
3.
There is airlock.
4.
The impeller is loose on the shaft.
5.
The impeller is broken.
Possible Cause
1. The fuse is blown.
2. The breaker is tripped.
3. The plug is disconnected.
4. The plug is corroded.
5. The motor failed.
1. The suction line is air leaked.
2. The impeller is clogged.
3. Did not fill water into pump.
4. Did not attach check-valve build-in
suction strainer to inlet hose.
1. The hose is kinked or coiled.
2. The strainer or hose is blocked.
3. The discharge hose is too long.
4. The impeller is broken.
Corrective Action
1.
Replace the fuse.
2.
Reset the breaker.
3.
Secure the plug.
4.
Clean the plug prongs.
5.
Replace the pump.
6.
Remove the blockage.
1.
Clean the screen.
2.
Straighten the hose.
3.
Clean the anti-air lock hole.
4.
Reassemble the impeller.
5.
Replace the impeller.
Corrective Action
1. Replace the fuse.
2. Reset the breaker.
3. Secure the plug.
4. Clean the plug prongs.
5. Replace the pump.
1. Repair suction line by tightening
hose connection or replacing
hose washer if necessary.
2. Remove the blockage.
3. Fill water into pump through
priming hole.
4. Use the special designed suction
strainer factory furnished to hose
end.
1. Straighten the hose.
2. Clean the strainer or hose.
3. Shorten the hose (50 ft. max).
4. Replace the impeller.
For Professional Technical Support call 1-844-242-2475