5
Electrical installation
8021852.1HTG/2022-11-11 | SICK
Subject to change without notice
NOTE
Swap the sender and receiver arrangement at every second photoelectric through-
beam sensor and ensure that there is sufficient distance between the through-beam
photoelectric sensors.
Sender (GS)
Receiver (GE)
Sender (GS)
Figure 3: Arrangement of several through-beam photoelectric sensors
The sensors must be connected in a voltage-free state (U
tion must be observed, depending on the connection type:
–
Male connector connection: pin assignment
–
Cable: wire color
Only apply voltage/switch on the voltage supply (U
tions have been established. The green LED indicator lights up on the sensor.
Explanations of the connection diagram (Tables 2 and 3):
Q / Q = switching outputs
n. c. = not connected
DC: 10... 30 V DC,
see "Technical specifications", page 27
Table 1: DC, GS
GS6-
1
2
3
4
OPERATING INSTRUCTIONS
> 0 V) once all electrical connec‐
V
D1xxxV
D4xxxV
+ (L+)
+ (L+)
n. c.
n. c.
- (M)
- (M)
n. c.
n. c.
3
1 = BN
4
2 = WH
3 = BU
4 = BK
0.14 mm
2
AWG26
O P E R A T I N G I N S T R U C T I O N S | GSE6V
Receiver (GE)
Sender (GS)
Receiver (GE)
= 0 V). The following informa‐
V
D7xxxV
+ (L+)
n. c.
- (M)
n. c.
1
2
1
2
3
4
en