REMEMBER
• Our mixers must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer
(see calculation table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce
the frequency of maintenance (recommended pressure from 1 to 5 bar (100 to 500 kPa) maximum).
• Install stopcocks close to the mixer to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should
be checked at least once a year, and more frequently if necessary.
TECHNICAL CHARACTERISTICS (FIG. B)
Flow rate:
• For basin mixers H9600/H9605:
Mixed Water temperature at 39°C at 3 bar pressure: 5 lpm.
• For sink mixers H9620/H9625:
Mixed Water temperature at 39°C at 3 bar pressure: 9 pm.
Safety:
• If the cold or hot water fails, the mixed water will shut off within 2 seconds.
• The anti-scalding safety is active if the temperature differential between the hot water and mixed water
is more than 15°C.
• Check the anti-scalding failsafe every two months and as often as necessary depending on the water
quality. Shut off the cold water and check that the hot water stops within 2 seconds.
When using a filtration device or similar system at the spout outlet or shower head, the flow rate must
be higher than 4 litres per minute to avoid cross flow between the hot and cold water.
Note : The anti-scalding safety is active if the cold water supply fails. If, instead of cold water, hot water
returns through another mixer, there is no anti-scalding safety. We recommend installing a non-return
valve on the cold water supply to the mixer.
MAINTENANCE & CLEANING
• Cleaning chrome, aluminium and stainless steel: do not use abrasive, chlorine or any other acid-
based cleaning products. Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the mixer/tap/valve several times to drain any
remaining water. In the event of prolonged exposure to frost, we recommend taking the mechanisms
apart and storing them indoors.
After Sales Care Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com
EN