Pressure REGULATOR (not supplied):
This appliance must be equipped with a pressure regulator in compliance with local/national standards and/or
regulations with a nominal pressure output of:
CATEGORY I3+(28-30/37) Propane 37 mbar. Butane 28-30 mbar.
CATEGORY I3B/P (30) Propane/Butane 30 mbar
CATEGORY I3B/P (50) Propane/Butane 50 mbar
NEVER USE AN UNREGULATED GAS SOURCE.
HOSE (not supplied):
The inlet pipe of the user must NOT be less than:
ؽ" = Ø14 mm for Methane
ؼ" = Ø 8 mm for LPG (Max length 1.5 meters)
CYLINDER
• We recommend using cylinders weighing no more than 10 kg if you want to place a trolley under the oven.
• Maximum length of the gas pipe allowed 1.5 m.
• Always handle the cylinder with care. Never place it in a horizontal position as the valve may become dama-
ged.
This could cause serious safety issues. Always use the cylinder upright. If positioned horizontally, the cylin-
der could allow the combustible liquid to reach the pipes, creating damage with risk of explosion.
• Always place the cylinder in an accessible place to facilitate opening and closing in case of emergency.
• Never subject cylinders to heat. The internal pressure could increase and exceed its safety limits.
• Never store butane or propane gas cylinders (even if empty) in the house, cellar or basement. Propane gas
is heavier than air, if there is a leak the gas will accumulate at the lowest level and become dangerous in the
presence of a spark or flame.
• Never store replacement or even empty Butane or Propane gas cylinders near the appliance in use "danger
of fire and/or explosion".