JBM 54339 Manual De Instrucciones página 7

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
REF.54339
When you reach the 85-90% of the target va-
lue, the green indicator will turn on and the
buzzer of the wrench will beep intermittently. If
you exceed the target value, reduce the force.
When the target value has been reached, a
red light will illuminate and the key will beep
continuously.
Torque and angle configuration in memory 
This wrench has six memories to configure
the torque and angle values (from M1 to M6).
Thanks to these memories you can quickly se-
lect the level of torque and angle you want.
You can see the memory number at the top left
of the screen.
For a new memory configuration, do the following.
Press M key to choose memory (from M1 to M6).
Keep the U key pressed.
Press the
keys to select the angle.
Press the C key.
Press the
keys to select the torque.
Backlight 
The screen light stays on for 5 minutes.
To turn the light back on, press any key.
Key lock 
With this function you can lock the tool
buttons. This way you can avoid accidentally
pressing a button. To lock, press and hold the
M key for 3 seconds.
To unlock, press and hold the M key for 3
seconds.
Viewing stored data
To view stored data, select peak mode.
Then, press the U key.
The display will show "C00".
Press the U key to view the stored data.
The display will flash, showing the torque level
and registration number alternately.
With the
keys you can navigate through
all stored data (up to 500 values can be re-
corded).
Press C to go to the main screen.
Turning off 
To turn off, keep pressed the C button.
MAINTENANCE
Do not use organic solvents to clean the wrench.
If you are not going to use the key for a while,
remove the batteries.
CONTENTS
- Dynamometric wrench
- Batteries (x2)
· 7 ·