DANGER
Electric shock
Death or serious
personal injury
- Power cables without a
plug must be
connected to a power
disconnecting device
incorporated in the
fixed wiring according
to the local wiring
rules.
2.4 Setting the pressure switch
DANGER
Electric shock
Death or serious
personal injury
- Switch off the power
supply before you
adjust the pressure
switch.
Fit the cover on the
pressure switch before
switching on the power
supply to check the
start and stop
pressures.
2.5 Fault finding
DANGER
Electric shock
Death or serious
personal injury
- Switch off the power
supply before you start
any work on the
product. Make sure
that the power supply
cannot be accidentally
switched on.
3. Applications
The CM Booster is suitable for pressure boosting of
clean fresh water in domestic water supply systems.
4. Sizing the system
CAUTION
Pressurised system
Minor or moderate personal injury
- Make sure that the system incorporating
the product is designed for the
maximum pump pressure.
For the default setting, see the quick
guide.
7