Grounding/Earthing Instructions
The oven MUST be grounded. Grounding reduces risk of electric shock
by providing a discharge wire for the electric current if an electrical short
occurs. This oven is equipped with a cord which includes a grounding
wire and grounding plug. The plug must be plugged into an outlet that is
properly installed and grounded.
Consult a qualified electrician or service technician if grounding
instructions are not clear or if there is any doubt as to whether the oven is
properly grounded.
Do not use an extension cord.
If the product power cord is too short, have a qualified electrician install a socket near the oven. This oven should
be plugged into a separate circuit with the electrical rating as provided in product specifications. When the
combination oven is on a circuit with other equipment, an increase in cooking times may be required and fuses can
be blown.
External equipotential earthing terminal
Equipment has secondary earthing terminal. Terminal provides external earthing connection used in
addition to earthing prong on plug. The terminal is located on outside of oven back and marked with
symbol shown on the right
For versions with power cable without plug, if direct installation to the power supply network is envisaged, disconnect
the line using a multi-pole switch with at least 3 mm (0.12 inches) disconnection according to Category III.
1,5 cm
[1/2"]
Oven clearances
A.
Allow at least 5 cm (2 inches) of clearance around top of oven. In the case
of two stacked ovens, 5 cm (2 inches) of space must be ensured above the
upper oven. Proper air flow around oven cools electrical components. With
restricted air flow, oven may not operate properly and life of electrical parts
is reduced. Provide air circulation holes in the cabinet if the oven is installed
built-in closed on the 5 sides.
B.
There is no installation clearance requirement for the back of the oven.
C. Allow at least 1,5 cm (1/2 inch) of clearance around sides of oven.
D. Install oven so oven bottom is at least 15 cm (5.9 inches) above floor.
GROUNDING AND INSTALLATION
5 cm
[2"]
1,5 cm
[1/2"]
90038780rev03
EN - 37 -
⚠
WARNING
To avoid risk of electrical shock or
death, this oven must be grounded
and plug must not be altered.
⚠
WARNING
Excessive weight hazard
Use two or more people to move and
install oven.
Failure to do so can result in back or
other injury
Oracle Net Weight 71 kg.