11
Technical data
11.1
Technical specifications
The "Technical Data" section contains only an extract of the technical data of the sensor.
The complete technical data can be found on the homepage
Features
Sensing range
Min. sensing range
Sensing range max.
Recommended sensing range for the best performance
1)
Object with 90% remission (based on standard white DIN 5033)
Emitted beam
Light sender
Type of light
Light spot size / distance
Communication interface
Table 14: Communication interface
IO-Link
IO-Link
Data transmission rate
Electrical data
Supply voltage U
B
Ripple
Current consumption
Protection class
1)
Limit values
Reverse polarity protected U
B
Residual ripple max. 5 V
ss
Digital output
Output current I
max.
Circuit protection
Max. response time
Switching frequency
1)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
2)
Signal transit time with resistive load
3)
Switching frequency and response time via IO-Link adjustable between 1 ... 50 Hz / 0.02 ... 0.5 s
4)
Depending on type
5)
With light / dark ratio 1:1
8027562/2022-02-28 | SICK
Subject to change without notice
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
connections
4)
www.sick.com
under the part number of the sensor.
WTS16-xxxxx3
50 mm ... 750 mm
100 mm ... 300 mm
WTS16-xxxxx3
PinPoint-LED
Sichtbares Rotlicht
8 mm / 300 mm
WTS16-xxxxx3
1.1
COM2
WTS16-xxxxx3
DC 10 ... 30 V
1)
≤ 5 Vss
≤ 30 mA, < 50 mA3
III
WTS16-xxxxx3
≤ 100 mA
A, B, C, D
1)
< 0.1 s
2)3)
10 Hz
5)3)
O P E R A T I N G I N S T R U C T I O N S | W16 MultiPulse
11
TECHNICAL DATA
1)
25
en