Drain the water from the boiler heating circuit.
•
Remove the flue connection (concentric or accessory for separate ducts)
•
Remove the fan
•
Remove the clips of the two pipes on the exchanger, pump and hydraulic unit
•
Remove the 2 top screws "5" securing the exchanger to the frame (fig. 41)
•
Loosen the 2 bottom screws "5" securing the exchanger to the frame (fig. 41)
•
Remove the exchanger
•
Fit the new exchanger on the bottom screws "5"
•
For assembly, proceed in reverse order
Disassembling the burner and cleaning the exchanger
3.5 mm
•
Disconnect the power supply and close the gas cock ahead of the valve.
•
Undo the 5 screws securing the exchanger cover.
•
Undo the 3 screws securing the burner.
•
Check the correct distance of the electrodes.
•
To clean the exchanger, it is advisable to remove the electrode (see fig. 45)
•
Clean the inside of the exchanger with the accessories indicated in fig. 42.
Do not use metal brushes which could damage the exchanger.
192
BLUEHELIX TECH RRT 24 H
fig. 42
cod. 3541C662 - Rev. 00 - 09/2020