Ferroli BLUEHELIX TECH RRT 24 H Instrucciones De Uso, Instalación Y Mantenimiento página 185

Ocultar thumbs Ver también para BLUEHELIX TECH RRT 24 H:
Idiomas disponibles
  • ES

Idiomas disponibles

BLUEHELIX TECH RRT 24 H
Contents Description
Timer for heating hysteresis after
P60
ignition
Pump deactivation with Open-
P61
Therm (ATTIVE ONLY WITH FW
3)
Notes:
1. Parameters with more than one description vary their function and/or range in relation to the setting of the parameter
given in brackets.
2. Parameters with more than one description are reset to the default value if the parameter given in brackets is mo-
dified.
3. The Maximum Heating Power parameter can also be modified in Test Mode.
Press the Reset button to return to the Service Menu. Press the Reset button for 20 seconds to exit the card Service
Menu, or exiting occurs automatically after 15 minutes.
"Sc" - Combustion Control Parameters Menu
ONLY QUALIFIED PERSONNEL CAN ACCESS THE "SC" MENU AND MODIFY THE RELEVANT PARAMETERS.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing order. Press the DHW buttons to
view or modify the value of a parameter. To save the edited parameter press either the heating"+" or "-" button (details
3 and 4 - fig. 1).
Con-
Description
tents
Sc01
Gas type selection
Sc02
Ignition gas calibration
Sc03
Ignition power
Sc04
Flue length
Sc05
Minimum power calibration
Sc06
Minimum gas valve calibration
Sc07
Flame ionization signal
Sc08
Current power ref. DHW
Sc09
MAX ionization value
Sc10
Minimum ionization value during ignition
Sc11
Ignition time
Sc12*
Ionization reduction value (BASE)
Sc13**
Ionization reduction value (min.)
Sc14
Internal error K1
Sc15
100% CALIBRATION
Sc16
DO NOT MODIFY.
EN
Range
60-180 seconds
0-1
Functional description
Allows the change of gas type. See "Gas conver-
sion" on page 177
Allows the amount of gas to be increased or decrea-
sed in the ignition phase in case of difficult starting.
Allows the fan speed to be increased or decreased
in the ignition phase in case of difficult starting.
Allows the boiler to be arranged according to the
width and length of the flue used. To be used only
with Ø50 or Ø60 flues. See fig. 27.
Allows the minimum power to be increased, if
necessary.
Self-adaptive parameter. DO NOT MODIFY.
Displays the actual ionization current signal.
Displays the actual power referred to maximum
power in DHW.
Displays the maximum ionization value reached.
Displays the minimum ionsation value reached
during the ignition phase.
Displays the time from fan activation to ionization.
Allows the adjustment of CO
maximum and minimum power, translating the entire
value curve.
Allows the adjustment of CO
Displays the SCOT system error code.
Allows 100% Calibration (see "100% calibration" on
page 178) when replacing some components (see
"Extraordinary maintenance and replacement of
components" on page 190)
cod. 3541C662 - Rev. 00 - 09/2020
Default
60 seconds
0
Range
na / LP
-9 ÷ 20
-16 ÷ 14
-2 ÷ 13
0 ÷ 25
Read only
Read only
Read only
Read only
Read only
at the same time as
2
-5 ÷ 10
at minimum power.
-5 ÷ 10
2
Read only
0 - CAL
Default
na
0
0
0
0
0
0
0
185
loading