ENGLISH
6 Configuring via WIFI
SMARTSHUNT has integrated WIFI hot spot to which
you can connect with smart phone or any other
device that allows web browsing. It can
automatically connected with scanning QR code
bellow serial number. You may get a message from
the system, that there may not be available internet
connection but just simply run your web browser and
type in
config.lxnav.com.
configuration page will show up. Before changing any
parameter, user should put SMARTSHUNT in config
mode. That means violet status LED must be lit. In
any other mode, settings will not be saved. For
enabling WIFI or putting it in config mode press
Config button for more than a second.
Configuration webpage that will show up consist of
four pages easily selectable on top of the screen:
Home, Battery config, Shunt config and Info page.
6.1.1
Homepage
On home page user can view all current data of
system in real time that are result of selected values
on config pages, for example voltages, temperatures,
current drawn, state of charge etc. as well as peak
recorded values and history of alarm messages.
6.1.2
Battery configuration
On this page user configures battery type with all
necessary data that are mandatory for correct
calculations of battery state and health.
Please do not access to the browser via QR
code for configuration, because browser does
not support popup windows and saving
configuration will not be possible.
The only way is to open browser and visit
config.lxnav.com. Then you can change and save
configuration settings.
be
With pressing enter,
Page 14 of 112
6.1.3
Shunt configuration page
All
the
necessary
measurements should be filled out in this page. There
is also button setting for desired WIFI action.
6.1.4
Info page
On this page are all information about device. Its
serial number, hardware and software version.
6.2
Configuration via LXNAV Exxx device
Second option for configuration of SMARTSHUNT is
via any Exxx device. Assuming that the NMEA2000
network
is
established
configuration pages are accessible under different
paths under setting menus. In following two chapters
are written paths where menus can be found and
their window previews. For operating and calibrating
external devices on Exxx units refer also to Exxx user
manual.
6.2.1
Battery setup
Parameters related to battery packs should be set in
menu that is accessible under this path:
Settings->Network->Device calibration->Battery
6.2.2
Shunt setup
Second configuration menu is found under:
Settings->Network->Connected devices->
Device details->Device setup
Parameters there relates to measurements between
shunt's terminals. There is also information about
WiFi hotspot name and password under which is
SMARTSHUNT accessible.
Inside shunt setup is submenu Alerts configuration
with user selectable parameters limits for warning
messages. There are seven warnings available in
total.
7 First operation
SmartShunt will start to operate normally and indicate
real values after initial cycle. Initial cycle is finished,
when first time are fulfilled conditions for battery full
(Voltage must be higher than voltage setting for full
and charge current must drop below full current
setting)
To get really good performance, smart shunt will
need more charge/discharge cycles, to tune also
other parameters like charge efficiency....
data
related
to
current
battery
and
shunt