Eurofred SE20-45 Manual De Instruccion página 10

Ocultar thumbs Ver también para SE20-45:
Idiomas disponibles
  • ES

Idiomas disponibles

The display will return to normal reading after 15 sec.
See table of parameters from page 24.
Alarm codes:
P1
Flashing in the display: indicates that the cabinet sensor is defective.
The cabinet will strive to keep the set temperature until it has been repaired.
HA Flashing in the display: indicates that the temperature is too high.
LA
Flashing in the display: indicates that the temperature is too low.
Defrosting
We recommend defrosting the freezer every three month or if the layer of ice exceeds 5 mm.
Do never use metal or other sharp objects to scrape the internal sides as it can damage the freezer
1. Disconnect the freezer
2. Empty the freezer
3. Leave the freezer with the lid open
4. Use the plastic scraper to remove the ice from the inner liner
5. Remove the drain plug and open the drain on the back side of the freezer and place a tray
under the drain
6. Clean the freezer with mild detergent and wipe thoroughly
7. Connect the freezer and it is ready for use.
Lock
The freezer is supplied with a lock in the handle
10
loading

Este manual también es adecuado para:

Se10-45Se30-45Se40-45Se10-45-p