Steinbach SPS 50-1T Manual Original página 24

Ocultar thumbs Ver también para SPS 50-1T:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66
An integrated prefilter prevents coarse dirt particles from entering the pump. This protects the pump
from damage.
Function principle of the timer
With the integrated timer, you can start and stop the pump automatically once a day for the set time. To
set several intervals within a 24-hour period, you need an external timer.
The timer has a battery (see section "Technical data"). The start time and the running time are saved in
case the power supply is interrupted or fails altogether.
Filtering time
The pool's water content should be circulated at least twice in a 24 h period. In case of heavier
frequency, the pool water should be circulated 3 to 5 times per day.
Before First Use
Risk of death when operating the water treatment system during bathing.
Hair or clothing might get sucked into the suction openings of the pool and in extreme cases
trap persons under water and prevent them from surfacing again.
- Never operate water treatment system devices while persons are in the pool.
- Prevent any access to the pool for as long as water treatment system devices are in use.
Check the following before start-up
- The device is out of the pool and the power cable is disconnected from the mains
Initial start-up of the timer
The timer is going to function flawlessly even if you do not perform the steps described below. However,
should the power supply be interrupted, the saved filter running times will be lost.
1. Make sure that the pump's power cable is disconnected from the power supply.
2. With a Phillips screwdriver PH1 , remove the screws of the timer cover and take the cover off.
3. Pull out the strip of plastic from underneath the battery.
4. Screw the cover back on.
The timer's memory backup function is activated.
Preparing the pump
At the time of delivery, the pump is only partially assembled.
Only hand-tighten all screw connections. Excessive tightening of the screw connections
damages gaskets and plastic components. Do not use any tools.
You can use Teflon tape to seal screw connections with minor leakage.
1. Loosen the threaded ring
cover
by turning it counterclockwise.
2
2. Lift the prefilter cover
off the pump housing.
3. Insert the large O-ring seal
on the pump housing.
4. Insert the prefilter
The prefilter is already inserted into the pump
at the factory.
5. Place the prefilter cover
housing.
6. Guide the threaded ring over the prefilter
cover.
24
on the prefilter
1
with the threaded ring
2
into the groove
3
into the pump.
11
on the pump
2
WARNING!
1
1
2
7
3
11
6
5
10
loading

Este manual también es adecuado para:

Sps 75-1tSps 100-1t