Lamborghini Caloreclima NINFA N LOW NOX 24 MCS Instrucciones De Uso, Instalación Y Mantenimiento página 73

Ocultar thumbs Ver también para NINFA N LOW NOX 24 MCS:
Idiomas disponibles

Idiomas disponibles

NINFA N LOW NOX 24 MCS
3. Service and maintenance
All adjustment, conversion, startup and maintenance operations described below must only be carried out by Qualified Per-
sonnel (meeting the professional technical requirements prescribed by current regulations) such as those of the Local After-
Sales Technical Service.
LAMBORGHINI declines any liability for damage and/or injury caused by unqualified and unauthorised persons tampering
with the unit.
3.1 Adjustments
Gas conversion
The unit can operate on Natural Gas or LPG and is factory-set for use with one of these two gases, as clearly shown
on the packing and on the dataplate. Whenever a different gas to that for which the unit is preset has to be used, a
conversion kit will be required, proceeding as follows:
1. Replace the nozzles at the main burner, inserting the nozzles specified in the technical data table in sec. 4.4, ac-
cording to the type of gas used
2. Modify the parameter for the type of gas:
put the boiler in standby mode
Press the RESET button (detail 6 - fig. 1) for 10 seconds: the display shows "TS" flashing
press the RESET button (detail 6 - fig. 1): the display shows "P01".
Press the DHW buttons fig. 1 (details 1 and 2 - ) to set parameter 00 (for operation with natural gas) or 01 (for
operation with LPG).
Press the RESET button (detail 6 - fig. 1) for 10 seconds.
the boiler will return to standby mode
3. Adjust the burner minimum and maximum pressures (ref. relevant paragraph), setting the values given in the tech-
nical data chart for the type of gas used
4. Apply the sticker contained in the conversion kit, near the dataplate as proof of the conversion.
TEST mode activation
Press the heating buttons fig. 1 (details 3 and 4 - ) together for 5 seconds to activate the TEST mode. The boiler
lights at the maximum heating power set as described in the following section.
The heating symbol (detail 14 - fig. 1) and DHW symbol (detail 8 - fig. 1) flash on the display; the heating power and
lighting power will be displayed alongside.
To deactivate the TEST mode, repeat the activation sequence.
TEST mode is automatically deactivated in any case after 15 minutes.
EN
fig. 21 - TEST mode (heating power = 100%)
cod. 3540R880 - 01/2009 (Rev. 00)
73