DOOR PANEL INSTALLATION
P
lace the nameplate labels.
If after starting the system it's considered that
the audio volume isn't correct, proceed
with the necessary adjustments as shown.
Use the included pan mechanism to adjust
the telecamera position.
C
lose the door panel.
Fix the door panel to the embedding box
by using the supplied vandal resistant screws
and the special screwdriver.
72
F
inal adjustments.
Monitor
Telephone
Door panel
73
POWER SUPPLY INSTALLATION
I
nstalling the FA-PLUS and FA-PLUS/C power supplies.
3,5 x 25
DIN-7971
To install the power supply directly on the wall, drill two holes
of Ø6 mm. and insert the wallplugs.
Fix the transformer with the specified screws.
3,5 x 25
DIN-7971
The power supply can be installed on a DIN 46277 guide
simply pressing it. To disassemble the power supply
from the DIN guide, use a plain screwdriver to lever
the flange as shown on the picture.
The FA-Plus/C model uses 6 units over DIN guide
and 10 units the FA-Plus model.
IMPORTANT: the maximum number of units that can be connected to a FA-Plus/C power
supply is 10, and 50 units in case of a FA-Plus model.
Link power supplies to connect more units than the specified as it's shown
on page 83.
LOCK RELEASE INSTALLATION
L
ock release installation.
If the lock release will be installed in a metal door, use a
Ø3,5mm. drill and tap the hole . In case of wood door,
use a Ø3mm. drill .
IMPORTANT: the lock release to be used must be of 12Vd.c.
If you are using a.c. lock releases, use one R-3 relay unit and
one TF-104 transformer to activate it, as it is shown on page 83.
The power supply must be installed in a dry and
protected place. It's recommended to protect
the power supply by using a thermo-magnetic
circuit breaker and to use a ground connection.
DIN 46277
3,5 x 25
DIN-7972
M 4 x 8
DIN-963