8) ADJUSTING DETECTION PATTERN
Adjust the detection pattern according to the following diagrams:
The DETECTION FIELD CHANGES DEPENDING ON THE TYPE OF
OBJECTS, MATERIAL, COLOUR AND SPEED.
1. Pattern Angle Adjustment.
MAX
SIDE VIEW/DETECTION PATTERN
2.0m
1.5m
1.0m 0.5m
Max Area
» The body of the sensor can be rotated from
0ºto 5º(3 Steps)
2. Pattern Width Adjustment
Mask Adjustments for single and/or double doors.
FRONTAL VIEW/DETECTION PATTERN
Pattern Width Adjustment
WIDE
(m )
2.0
1.5
1.0
0.5
0.5 1.0 1.5
INSTALLATION MANUAL
2.0m
1.5m
1.0m 0.5m 0m
0m
0
0.5m
1.0m
1.5m
2.0m
2.5m
3.0m
Min Area
NARROW
2.0
2.0
1.5
1.0
0.5
0.5 1.0 1.5
0
0.5m
1.0m
1.5m
2.0m
2.5m
3.0m
9) OPERATION CHECK
1. Having installed the appliance, set the parameters and supplied
the current, carry out a test to check detection field operation.
2. If the sensor does not operate correctly, recheck the commutator
settings and adjust the detection field.
3. If any problems remain unsolved after a new check, adjust the
sensitivity level.
Sensitivity
MIN
Turn clockwise to increase sensitivity.
Turn anticlockwise to decrease sensitivity.
10) SELF-DIAGNOSIS
When the RIP sensor reception devices receives the infrared rays, the
relay switches between ON and OFF for 12 seconds (4 times in 12
seconds), then it stays on for 60 seconds and subsequently starts a
new cycle.
At the same time, the luminous indicator switches between RED and
GREEN.
During these operations, the door will stay open.
Relay Output Timing Chart
(When no refrection)
12 s
ON
OFF
EXTREMELY IMPORTANT
After completing the installation, carry out a thorough check of
the unit/s to ensure that the detection area is fully covered (check
width, depth and position of the detection field).
11) DISPOSAL
ATTENTION: disposal should only be carried out by qualified
personnel.
Materials must be disposed of in conformity with the current regulations.
In case of disposal, the system components do not entail any particular
risks or danger. In case of recovered materials, these should be sorted
out by type (electrical components, copper, aluminium, plastic etc.).
The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any
2.0
alterations deemed appropriate for the technical, manufacturing
and commercial improvement of the product, while leaving its
essential features unchanged, at any time and without undertaking
to update the present publication.
High
60 s
12 s
1 cycle
ENGLISH
RIP - Ver. 02 - 7