Electrical Installation - Pentair MAGICSTREAM Guia De Instalacion

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
Pentair recommends that the system pressure test be performed after the deck housing is mounted to the supply piping.
5. Plug the flex line in the housing by disconnecting the union between the deck housing and
the Laminar. Using one of the Laminar adjustment nuts, secure the winterization cap to the
supply side of the union. Make sure the connection surface between the flex lines are open
and clean.
The pressure on the piping/plumbing supplying the Laminar should not exceed 3.5BAR.
6. Once the deck is finished, flush any debris from the supply pipe using the pump and filter
system that supplies the Laminar.
Any debris in the Laminar unit will hinder its ability to produce a turbulence-free stream.

Electrical Installation

1. Pull the 14 gauge, 2-conductor cable through the opening marked "electrical" in the deck
housing and route it, via electrical conduit, to the transformer location (Figure 2).
Leave 1 meter of slack at the deck housing end to allow for servicing.
2. Connect the LED wiring to the 12 Volt AC taps of the transformer.
3. Connect the 220 VAC side of the transformer to a 220 VAC GFCI power feed that is controlled
by a single switch. When installing multiple laminars, make sure all the laminars are
connected to a single switch.
WARNING
To avoid dangerous or fatal electrical shock hazard, all metal items within 1.5meter of the
pool or spa must be properly electrically bonded to a reliable grounding point. The Laminar canister must be
properly electrically bonded and grounded via the NO. 8 AWG ground connector located on the side of the
canister.
Transformer
location
Figure 2
Filter
Pull 2-conductor cable
through the opening
marked "electrical" in
the deck housing and
feed it via electrical
conduit to the
transformer's
location.
13
Ground wire
Rebar
Tabla de contenido