Pentair MAGICSTREAM Guia De Instalacion página 21

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
Troubleshooting
(MagicStream
Symptom
The light will not
illuminate.
Light does not function prop-
erly.
What Mode is the light in?
Troubleshooting (IntelliBrite
Symptom
Both of the LEDs are flashing. The IntelliBrite Controller has detected that the load has exceeded the
The light will not
illuminate.
Light does not function prop-
erly.
Laminar)
®
Check the GFCI ground fault wiring and reset if
necessary.
Check the light wiring connection to the junction
box at the pool side and to the AC power switch.
Be sure that there is proper AC power applied
to the light.
Turn the switch Off/On 17 times. This will put the light in
IntelliBrite Mode, fixed on white, Random Mode off and Thumper on.
From there you can set the desired mode.
Controller)
®
maximum allowable wattage or the output is shorted out
1. Switch off the IntelliBrite Controller OFF. Remove
excessive load or short.
2. Press the IntelliBrite Controller power switch to power on the unit.
Ensure that the LEDs are no longer flashing.
Check the ground fault wiring and reset if necessary.
Check the light wiring connection to the junction box at the pool side and
to the main circuit breaker.
Be sure that there is proper AC power applied to the light.
21
Action
Action
Tabla de contenido
loading

Tabla de contenido