The MicroBrite light adaptor allows the mounting of the MicroBrite Light in the 1-1/2"
return fitting. Refer to the Compatible MicroBrite Light Wall Fittings table above.
FOR FIBER OPTIC RETROFIT APPLICATIONS SEE PAGE 10.

WET CONDUIT INSTALLATION

Note: MicroBrite lights are shipped from the factory with the white threaded adaptor
ring pre-installed onto the body of the light. The male threads on the white threaded
adaptor ring allow the light to be threaded into the female threads of most 1-1/2"
(1.5") pool wall return fittings. To install the MicroBrite Light wall fitting into a
concrete/gunite pool:
1.
To install a MicroBrite Light, route the MicroBrite light power cord light cable
through the 1.5" wall fitting to the location of the 12 VAC pool transformer or
junction box.
2.
Wrap plumber's thread sealant tape around the male threads on the white
threaded adaptor ring on the light.
3.
Pull the MicroBrite power cord through the conduit so there is approximately
three to six inches of visible cord between the body of the MicroBrite light and
the wall fitting.
Wrap threaded sealant
tape around the
adaptor
Continue to Step 4 on next page.
MicroBrite Color and White Light Installation and User's Guide
Part No.
SP1022
215-9170B
400-9150B
215-9890B
400-9170B
CMP25550001060
CMP25522100000
CMP25550000000
Description
Hayward
WaterWay
®
WaterWay
WaterWay
WaterWay
CMP
CMP
CMP
1-1/2" Standard
Wall Fitting
Tabla de contenido
loading

Tabla de contenido