Viega 6171.10 Instrucciones De Instalación página 26

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
Instruction for use Multiplex
GB
D
Assembly
m 560 mm, 725 mm,
1070 mm:
Push the top end of the
overflow pipe into the
rubber sleeve.
Push the union nut, seal
ring and wedge seal
onto the bottom end
of the drain elbow and
screw tight.
p Cut the drain elbow if
the wastewater pipe
should only have a
diameter of 40 mm.
s Check the drain fitting
for leaks after assembly.
E
Assembly of the equipment set
 Set the valve cone using
the adjusting screw and
counter using the union
nut.
d Remove rotatable collar
and push it in as far as
it will go in the position
shown.
F
Setting the rise in the water level
 Presentation of rotatable
collar without water level
increasing function.
d The overflow function is
deactivated by pulling
① or turning ② the
rotatable collar.
n 560 mm, 725 mm:
The pipe must be
inserted at least 1.5 cm
into the sleeve and the
drain.
q Push sliding ring and
seal ring onto the
drainage elbow. Screw
the drainage elbow onto
the odour trap using the
union nut.
 Remove red protective
foil. Insert valve cone.
Insert rotatable collar
(not all the way).
e Turn rotatable collar to
left, valve cone closed.
 The water increase is
activated by pressing
the rotatable collar.
26
o 1070 mm:
The pipes must be
inserted at least 1.5 cm
into the sleeve and the
drain.
r Adjust the odour trap
and connect to the
wastewater system.
 Turn rotatable collar
to the left as far as it
will go. The valve cone
closes.
f Turn rotatable collar to
right, valve cone open.
 Presentation of rotatable
collar with water level
increase.
loading

Este manual también es adecuado para:

6171.116171.12724566724573733582733599