Ravelli DUAL 9 SUPER Manual De Uso Y Mantenimiento página 51

Idiomas disponibles
  • ES

Idiomas disponibles

Rev.1 26/03/2018
Pag.51
EN
ATTENTION!
When extraction fans (example: extraction hoods) are used in the same room or space as the stove, this can
cause problems to stove operation.
The stove must be installed on a floor with suitable load capacity. If the existing position does not fulfil this
requirement, it is necessary to take due measures (for example, using a load distribution plate).
ATTENTION!
provide due insulation if the surface is made of flammable material.
If the side walls adjacent to the stove are made of a flammable material, it will be necessary to position the stove at least 30 cm from
them.
Minimum clearances from combustible materials
R Right side
150 mm
L Left side
150 mm
B Rear
100
A Front
> 800 mm
If the floor that the stove is standing on is flammable, we recommend duly insulating it. Objects and parts that are heat-sensitive or
flammable cannot be stored near the stove; in any case keep these objects at a minimum frontal distance of 100 cm from the most
external point of the appliance's footprint.
Stove installation must guarantee easy access to clean the appliance, the exhaust ducts and the chimney.
Use and maintenance manual Dual 9 super
L
R
A
B
loading