EN
8. PROGRAMMING
To access programming, press button F for 2 seconds.
Programming is divided into 4 levels.
To go to the ne t level keep button F pressed and press the + key (Sequence 1-2-3-4-1.......).
After selecting the level wanted, press button F to display the functions available in consecutive order. Each time F is pressed the menu shifts
to the ne t function ( - - .....)
With the function selected, use the
The changes made to the parameters are active immediately, but will be permanently saved only when e iting the menu, selecting the ST
function with key F.
NOTE: In case of power failure during programming, all changes will be lost.
2"
F
1st level
programming
+
+
F
2nd level
programming
+
+
F
4th level
programming
+
+
F
Control unit
8.1 BASIC FUNCTIONS
+
-
or
key to change the value of the parameter (
Selects each single
F
1st level function
(see table par.8.2)
Selects each single
F
2nd level function
(see table par.8.3)
Selects each single
F
4th level function
(see table par.8.5)
E ample:
Selecting Output2 set to closed arm:
A
B
+
2"
+
F
F
F
2
nd
level
+
Changes the values
-
+
of each single 1st
level function
(see table par.8.2)
F
Changes the values
-
+
of each single 2nd
level function
(see table par.8.3)
F
Changes the values
-
+
of each single 4th
level function
(see table par.8.5)
F
C
D
5
4
+
=bollard closed
- 34 -
-
: ---... /
: ...---).
F
F
E
3
F
-
+
"" function
E it and save
programming