Commercial Sand Filters Installation and Operation Manual Contents Safety Instructions..1 General......3 Installation.....4 Operation.......6 Replacement Parts..7 Warranty.......10 HCF342C HCF348C HCF455C HCF663C Hayward Industries 1415 Vantage Park Dr., Suite 400 Charlotte, NC 28203 Phone: (908) 355-7995 www.hayward.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Página 2
In addition to two or more suction outlets per pump installed in accordance with latest APSP standards and CPSC guidelines, follow all national, state, and local codes applicable. • Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Página 3
Contact a licensed electrician or building inspector for information on local electrical codes for bonding requirements. • Verify water discharge from the filter manual air relief valve is directed away from electrical devices. • Do not locate pump controls over or near filter. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Página 5
FRP filters can be damaged during transportation and it is the responsibility of the installer to inspect at the time of delivery. Damages to filters from transportation that are not noted on the bill of lading are not covered by Hayward’s warranty policy and all costs to repair will be the responsibility of the owner.
Página 6
It is important to test the system without sand first, to check for leaks. Open the vent valve. Fill the system with water. When water stream (not water and air) is discharged from the vent valve, close vent valve. Run system as normal and check for leaks. If there is a problem with the test, contact Hayward customer service immediately.
Página 7
Using a hose, spray the sand to loosen if necessary. Clean remaining sand from the walls as best as possible with a hose and vacuum. Add the new sand as required in the table on page 4. Replace the manway cover and seal. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Página 9
Water Drain Plug O-Ring HCXFWDPOR012B Water Drain Plug O-Ring HCXFWDPCKIT013 Water Drain Plug & O-Ring Kit HCXFWDPCKIT013 Water Drain Plug & O-Ring Kit HCXFWDPCKIT014 Media Drain Cap & O-Ring Kit HCXFWDPCKIT014 Media Drain Cap & O-Ring Kit USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Página 10
HCXFW2BHG307A 3" Bulkhead Gasket (2 Pack) HCXFW2UNAOR309A 3" Union O-Ring (2-Pack) HCXFW2UNAOR309A 3" Union O-Ring (2-Pack) HCXFWDPCKIT010 Media Drain Cap Kit HCXFWDPCKIT010 Media Drain Cap Kit HCXFWLATKIT511 HCF455C Lateral Kit HCXFWLATKIT611 HCF663C Lateral Kit USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Página 11
® To buyer, as original purchaser of this equipment, Hayward Pool Products, 400 Connell Drive, Suite 6100, Berkeley Heights, NJ 07922 warrants its products free from defects in materials and workmanship for a period of FIVE (5) years from the date of purchase.
Página 13
Manuel d’installation et d’utilisation Sommaire Consignes de sécurité..1 Général.......3 Installation......4 Opération......6 Pièces de rechange.....7 Garantie......10 HCF342C HCF348C HCF455C HCF663C Hayward Industries 1415 Vantage Park Dr., Suite 400 Charlotte, NC 28203 Tél : 908-355-7995 www.hayward.com N’UTILISER QUE DES PIÈCES DE RECHANGE HAYWARD D’ORIGINE...
Página 14
En plus de deux sorties d’aspiration ou plus par pompe installées conformément aux dernières normes anciennement APSP et aux directives de la CPSC, respectez tous les codes nationaux, régionaux et locaux applicables. • Il est recommandé d’installer un système brise-vide ou de ventilation qui libère l’aspiration. N’UTILISER QUE DES PIÈCES DE RECHANGE HAYWARD D’ORIGINE...
Página 15
Vérifiez que l’évacuation d’eau de la vanne de décharge d’air manuelle du filtre est dirigée loin des appareils électriques. • Ne placez pas les commandes de la pompe au-dessus du filtre ni à proximité. N’UTILISER QUE DES PIÈCES DE RECHANGE HAYWARD D’ORIGINE...
Página 16
L’élimination des « eaux usées » doit être conforme aux codes locaux, régionaux et nationaux. • Voir le graphique de la page 4 pour le dégagement vertical et horizontal. Tuyauterie minimale recommandée par Hayward pour les filtres Modèle de filtre Taille de l’orifice...
Página 17
Les dommages causés aux filtres par le transport et qui ne sont pas notés sur le connaissement ne sont pas couverts par la politique de garantie de Hayward et tous les coûts de réparation seront à la charge du propriétaire.
Página 18
Faites fonctionner le système normalement et vérifiez l’absence de fuites. En cas de problème avec le test, contactez immédiatement le service clientèle de Hayward. Si du sable est ajouté avant le test et qu’il y a un problème avec le filtre, le sable devra être évacué afin d’inspecter les dommages potentiels.
Página 19
Nettoyez le sable restant sur les murs du mieux possible avec un tuyau et un aspirateur. Ajoutez le nouveau sable comme indiqué dans le tableau de la page 4. Remettez en place le couvercle et le joint du trou d’homme. N’UTILISER QUE DES PIÈCES DE RECHANGE HAYWARD D’ORIGINE...
Página 20
Taille des tuyaux Débit en gpm et (lpm) Taille des tuyaux Débit en gpm et (lpm) 2 po (63 mm) 90 gpm (340 lpm) 4 po (100 mm) 350 gpm (1325 lpm) 3 po (90 mm) 200 gpm (757 lpm) 6 po (150 mm) 800 gpm (3028 lpm) N’UTILISER QUE DES PIÈCES DE RECHANGE HAYWARD D’ORIGINE...
Página 21
Kit bouchon de drainage d’eau et joint torique HCXFWDPCKIT013 Kit bouchon de drainage d’eau et joint torique HCXFWDPCKIT014 Kit capuchon de drainage des fluides et joint torique HCXFWDPCKIT014 Kit capuchon de drainage des fluides et joint torique N’UTILISER QUE DES PIÈCES DE RECHANGE HAYWARD D’ORIGINE...
Página 22
Joint torique pour union 3 po (paquet de 2) HCXFW2UNAOR309A Joint torique pour union 3 po (paquet de 2) HCXFWDPCKIT010 Kit capuchons de drainage des fluides HCXFWDPCKIT010 Kit capuchons de drainage des fluides HCXFWLATKIT511 Kit latéral Kit latéral HCXFWLATKIT611 455CHCF 663CHCF N’UTILISER QUE DES PIÈCES DE RECHANGE HAYWARD D’ORIGINE...
Página 23
Aucun retour ne peut être effectué directement à l’usine sans l’autorisation écrite expresse de Hayward Pool Products. Hayward ne sera pas responsable du transport, de la main d’œuvre pour le retrait et/ou la réinstallation ou de tout autre coût encouru pour obtenir des rem- placements sous garantie.
Página 25
Manual de instalación y operación Contenido Instrucciones de seguridad..1 General.......3 Instalación......4 Funcionamiento....6 Piezas de repuesto....7 Garantía......10 HCF342C HCF348C HCF455C HCF663C Hayward Industries 1415 Vantage Park Dr., Suite 400 Charlotte, NC 28203 Teléfono: (908) 355-7995 www.hayward.com UTILIZAR SOLAMENTE PIEZAS DE REPUESTO ORIGINALES DE HAYWARD...
Página 26
Además de instalar dos o más bocas de salida de succión por bomba, de acuerdo con los últimos estándares de APSP y lineamientos de CPSC, siga todos los códigos nacionales, estatales y locales aplicables. • Se recomienda la instalación de un sistema de liberación de vacío o ventilación, que alivia la succión obstruida. UTILIZAR SOLAMENTE PIEZAS DE REPUESTO ORIGINALES DE HAYWARD...
Página 27
Verifique que la descarga de agua de la válvula de alivio de aire manual del filtro no apunte en la dirección de los dispositivos eléctricos. • No localice los controles de la bomba sobre el filtro o cerca de él. UTILIZAR SOLAMENTE PIEZAS DE REPUESTO ORIGINALES DE HAYWARD...
Página 28
HCF342C Brida/unión de 3 in Calibre 40 de 3 in HCF348C Brida/unión de 3 in Calibre 40 de 3 in HCF455C Brida de 4 in Calibre 40 de 4 in HCF663C Brida de 6 in Calibre 40 de 6 in UTILIZAR SOLAMENTE PIEZAS DE REPUESTO ORIGINALES DE HAYWARD...
Página 29
Los daños en los filtros debido al transporte de los que no se deje constancia en la orden de embarque no estarán cubiertos por la política de garantía de Hayward y todos los costos de reparación serán responsabilidad del dueño.
Página 30
(no agua y aire) desde la válvula de ventilación, cierre la válvula de ventilación. Haga funcionar el sistema con normalidad y verifique si hay fugas. Si hay algún problema con las pruebas, comuníquese con el servicio al cliente de Hayward de inmediato. Si se agrega arena antes de la prueba y hay algún problema con el filtro, deberá...
Página 31
Limpie la arena restante de las paredes lo mejor posible con una manguera o aspiradora. Agregue la arena nueva según lo indicado en la tabla de la página 4. Reemplace la cubierta de la escotilla y el sello. UTILIZAR SOLAMENTE PIEZAS DE REPUESTO ORIGINALES DE HAYWARD...
Página 32
Tamaño de la tubería Índice de flujo en gpm y (lpm) 2 in (63 mm) 90 gpm (340 lpm) 4 in (100 mm) 350 gpm (1325 lpm) 3 in (90 mm) 200 gpm (757 lpm) 6 in (150 mm) 800 gpm (3028 lpm) UTILIZAR SOLAMENTE PIEZAS DE REPUESTO ORIGINALES DE HAYWARD...
Página 33
Kit de junta tórica y tapón de drenaje de agua HCXFWDPCKIT014 Kit de junta tórica y tapa de drenaje de medios HCXFWDPCKIT014 Kit de junta tórica y tapa de drenaje de medios UTILIZAR SOLAMENTE PIEZAS DE REPUESTO ORIGINALES DE HAYWARD...
Página 34
Junta tórica de unión de 3 in (paquete de 2) HCXFWDPCKIT010 Kit de tapa de drenaje de medios HCXFWDPCKIT010 Kit de tapa de drenaje de medios HCXFWLATKIT511 Kit lateral HCF455C HCXFWLATKIT611 Kit lateral HCF663C UTILIZAR SOLAMENTE PIEZAS DE REPUESTO ORIGINALES DE HAYWARD...
Página 35
No se pueden realizar devoluciones directamente a la fábrica sin la autorización expresa por escrito de Hayward Pool Products. Hayward no será responsable por el transporte, la extracción, los trabajos de instalación o cualquier otro tipo de costos en los que se haya incurrido para obtener repuestos en garantía.