Troubleshooting
If your appliance develops a fault, please check the following table before making a call to your retailer.
Fault
The appliance is not working
The appliance is not working
The appliance turns on, but
the
temperature
is
high/low
The appliance is leaking
water
The appliance is unusually
loud
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Too much ice on the evaporator
Condenser blocked with dust
Doors are not shut properly
Appliance is located near a heat source or
too
air flow to the condenser is being
interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being stored in
the appliance
Appliance is overloaded
The appliance is not properly levelled
The discharge outlet is blocked
Movement
of
water
obstructed
The water container is damaged
The drip tray is overflowing
Loose nut/screw
The appliance has not been installed in a
level or stable position
IN CASE THE SUPPLY CABLE IS DAMAGED, THE MANUFACTURER OR THE AFTER-SALES
SERVICE, OR QUALIFIED TECHNICIAN SHALL REPLACE IT, IN ORDER TO PREVENT ANY
POSSIBLE RISK.
THE LAMP REPAIR AND REPLACEMENT SHALL BE CARRIED OUT BY QUALIFIED
TECHNICIANS, WITH POWER SUPPLY DISCONNECTED. REPLACE WITH IDENTICAL LAMPS.
ONLY QUALIFIED TECHNICIANS SHALL CARRY OUT THE EXTRAORDINARY MAINTENANCE
INTERVENTIONS.
Action
Check the unit is plugged in correctly and
switched on
Call your agent or qualified Technician
Replace the fuse
Check power supply
Call your agent or qualified Technician
Defrost the appliance
Call your agent or qualified Technician
Check doors are shut and seals are not damaged
Move the appliance to a more suitable location
Increase ventilation or move appliance to a
cooler position
Remove ant excessive hot foodstuff or blockages
to the fan
Reduce the amount of food stored in the
appliance
Adjust the screw feet to level the appliance (if
applicable)
Clear the discharge outlet
to
drain
is
Clear the floor of the appliance (if applicable)
Call your agent or qualified Technician
Empty the drip tray (if applicable)
Check and tighten all nuts and screws
Check installation position and change is
necessary
loading