8. PROGRAMMING OF THE CYCLES IN REGENERATION MODE
The dip switches on the card are used to enter the regeneration cycles (when the set parameter is reached the
LED lights up). We suggest to set the regeneration as first phase and then set the remaining dip switches. If no
programming is done, the card will not count the cycles.
How to proceed
Machine status: machine off (no power supplied), door open.
Set the dip switches to choose the number of cycles for the regeneration alarm.
See table:
After having set the dip switches, turn on the main power switch and press button A-2 simultaneously. Wait until the
cycle LED light (A-5) is off and then release button A-2. Now the new cycle parameters are saved. You may change
the cycle parameters during the programming phase using the dip switches. Return dip switches in the original
condition. After having set the parameters wait approx. 1 second and turn of the main power. The machine
increases the number of cycles at each new cycle and when the set number is reached the A-5 LED blinks. You
can stop this alarm only by starting the regeneration cycle.
9. Detergent injector in the tank
The machine is ready to be equipped with a detergent injector through a hole with a diameter of 8,5 on the back
side of the tank. We recommend not to add other holes and, if necessary, remove the external panels before
drilling.